PC Makrolon® 9417C 012124 COVESTRO SHANGHAI
192
- Unit Price:US$ 3,399 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:10MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:Flame retardant|transparent|Filler: Glass fiber reinforced material|10% filler by weight|10% filler by weight
- Application Areas:Automotive components
- Color:--
- Grade:Injection grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ISO 294-4 | 0.45 % | |
ISO 2577 | 0.40-0.60 % | ||
ISO 2577 | 0.40-0.60 % | ||
melt mass-flow rate | ISO 1133 | 7.0 g/10min | |
Melt volume flow rate | ISO 1133 | 6.00 cm3/10min | |
Water absorption rate | ISO 62 | 0.10 % | |
density | ISO 1183 | 1.27 g/cm³ | |
Apparent density | ISO 60 | 0.64 g/cm³ | |
Shrinkage rate | ISO 294-4 | 0.60 % | |
Water absorption rate | ISO 62 | 0.26 % |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
ball-indentation hardness | ISO 2039-1 | 128 Mpa |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
Hot filament ignition temperature | IEC 60695-2-13 | 825 °C | |
IEC 60695-2-13 | 900 °C | ||
IEC 60695-2-13 | 900 °C | ||
Limiting Oxygen Index | ISO 4589-2 | 35 % | |
Burning rate - US-FMVSS | ISO 3795 | passed | |
ApplicationofFlamefromSmallBurner-Method | DIN 53438-1,-3 | K1.F1 | |
FlashIgnitionTemperature | ASTM D1929 | 470 °C | |
SelfIgnitionTemperature | ASTM D1929 | 550 °C | |
Burning wire flammability index | IEC 60695-2-12 | 960 °C | |
IEC 60695-2-12 | 960 °C | ||
IEC 60695-2-12 | 960 °C | ||
UL flame retardant rating | UL 94 | 5VA | |
UL 94 | 5VA | ||
UL 94 | V-0 |
Supplementary Information | Test Condition | Test Method | Test Result |
---|---|---|---|
electrolytic corrosion | IEC 60426 | A1 |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179/1eU | 120 kJ/m² | |
Multi axis Instrumented Impact Energy | ISO 6603-2 | 15.0 J | |
Impact strength of cantilever beam gap | ISO 7391 | 10 kJ/m² | |
Impact strength of simply supported beam without notch | ISO 179/1eU | 150 kJ/m² | |
ISO 179/1eU | 100 kJ/m² | ||
Charpy Notched Impact Strength | ISO 7391 | 10 kJ/m² | |
Multi axis Instrumented Impact Energy | ISO 6603-2 | 25.0 J | |
Multi axis Instrumented Peak Impact Force | ISO 6603-2 | 4000 N | |
ISO 6603-2 | 3700 N |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Bending Strain | ISO 178 | 5.8 % | |
bending strength | ISO 178 | 105 Mpa | |
ISO 178 | 95.0 Mpa | ||
Flexural modulus | ISO 178 | 3600 Mpa | |
Tensile modulus | ISO 527-2/1 | 3800 Mpa | |
tensile strength | ISO 527-2/5 | 64.0 Mpa | |
ISO 527-2/5 | 45.0 Mpa | ||
Tensile strain | ISO 527-2/5 | 4.6 % | |
ISO 527-2/5 | 15 % | ||
Tensile creep modulus | ISO 899-1 | 2900 Mpa | |
ISO 899-1 | 3600 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
relative permittivity | IEC 60250 | 3.20 | |
IEC 60250 | 3.20 | ||
dielectric strength | IEC 60243-1 | 36 KV/mm | |
Volume resistivity | IEC 60093 | 1E+16 ohms·cm | |
Surface Resistivity | IEC 60093 | 1E+16 ohms | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 4 | |
IEC 60112 | PLC 3 | ||
Dissipation Factor | IEC 60250 | 1E-03 | |
IEC 60250 | 9E-03 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Linear coefficient of thermal expansion | ISO 11359-2 | 6.5E-05 cm/cm/°C | |
RTI Str | UL 746 | 125 °C | |
RTI Imp | UL 746 | 115 °C | |
thermal conductivity | ISO 8302 | 0.22 W/m/K | |
RTI Elec | UL 746 | 125 °C | |
Heat distortion temperature | ISO 75-2/B | 141 °C | |
vicat | ISO 306/B50 | 143 °C | |
ISO 306/B120 | 144 °C | ||
ball-indentation hardness | IEC 60695-10-2 | Pass | |
Heat distortion temperature | ISO 75-2/A | 135 °C | |
Linear coefficient of thermal expansion | ISO 11359-2 | 4E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App
Top