PC LEXAN™ 4701R-70007 SABIC INNOVATIVE NANSHA
238
- Unit Price:US$ 5,001 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:18.8MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:High temperature resistance|transparent
- Application Areas:Electronic and electrical components
- Color:--
- Grade:--
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Refractive index | ASTM D542 | 1.600 | |
| transmissivity | 2540 μm | ASTM D1003 | 85.0 % |
| turbidity | 2540 μm | ASTM D1003 | 1.0 % |
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D1822 | 577 kJ/m² | |
| Dart impact | 23°C | ASTM D3029 | 149 J |
| Suspended wall beam without notch impact strength | 23°C | ASTM D4812 | 3200 J/m |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| bending strength | Yield, 50.0 mm Span | ASTM D790 | 97.0 Mpa |
| Bending modulus | 50.0 mm Span | ASTM D790 | 2330 Mpa |
| elongation | Break | ASTM D638 | 78 % |
| tensile strength | Break | ASTM D638 | 77.0 Mpa |
| Yield | ASTM D638 | 65.0 Mpa |
| injection | Test Condition | Test Method | Test Result |
|---|---|---|---|
| drying temperature | 120 °C | ||
| drying time | 3.0 to 4.0 hr | ||
| Suggested maximum moisture content | 0.020 % | ||
| Suggested injection volume | 40 to 60 % | ||
| Temperature at the rear of the barrel | 325 to 350 °C | ||
| Temperature in the middle of the barrel | 340 to 360 °C | ||
| Temperature at the front of the material cylinder | 350 to 370 °C | ||
| Spray nozzle temperature | 345 to 365 °C | ||
| Processing (melt) temperature | 350 to 370 °C | ||
| Mold temperature | 80 to 115 °C | ||
| Back pressure | 0.300 to 0.700 Mpa | ||
| Screw speed | 40 to 70 rpm | ||
| Exhaust hole depth | 0.025 to 0.076 mm |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| RTI | UL 746 | 130 °C | |
| RTI Imp | UL 746 | 130 °C | |
| RTI Elec | UL 746 | 130 °C | |
| thermal conductivity | ASTM C177 | 0.21 W/m/K | |
| specific heat | ASTM C351 | 1260 J/kg/°C | |
| Linear coefficient of thermal expansion | -40 to 95°C,Flow | ASTM E831 | 8.1E-5 cm/cm/°C |
| Hot deformation temperature | 1.8 MPa, Unannealed, 3.20 mm | ASTM D648 | 148 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Specific volume | ASTM D792 | 0.830 cm³/g | |
| melt mass-flow rate | 300°C/1.2 kg | ASTM D1238 | 2.0 g/10 min |
| Water absorption rate | 24 hr | ASTM D570 | 0.19 % |
| Shrinkage rate | 3.20 mm,Flow | Internal Method | 0.80 - 1.0 % |
| melt mass-flow rate | 300°C/6.1 kg | ASTM D1238 | 9.0 g/10 min |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Dielectric constant | 1 MHz | ASTM D150 | 3.10 |
| Dissipation factor | 50 Hz | ASTM D150 | 1.6E-3 |
| 60 Hz | ASTM D150 | 1.6E-3 | |
| Dielectric constant | 50 kHz | ASTM D150 | 3.27 |
| 60 Hz | ASTM D150 | 3.27 | |
| Dielectric strength | 3.20 mm, in Air | ASTM D149 | 20 KV/mm |
| Volume resistivity | ASTM D257 | > 2.5E+17 ohms·cm | |
| Dissipation factor | 100 Hz | ASTM D150 | 0.026 |
| Arc resistance | ASTM D495 | PLC 6 | |
| Compared to the anti leakage trace index | UL 746 | PLC 3 | |
| High arc combustion index | UL 746 | PLC 3 | |
| High voltage arc tracing rate | UL 746 | PLC 3 | |
| Hot wire ignition | UL 746 | PLC 2 |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Rockwell hardness | R-Scale | ASTM D785 | 127 |
| M-Scale | ASTM D785 | 92 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.