PSU UDEL® GF-130 NT SOLVAY USA
293
- Unit Price:US$ 14,590 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:10.5MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:Hydrolysis resistance|Chemical resistance|Filler: Glass fiber reinforced material
- Application Areas:Home appliance components|Industrial components|Electrical appliances|Valves/valve components|Pipeline components|Microwave cooker|Home appliance components|Electrical components|Food service sector|Electrical/Electronic Applications|Industrial components|Vehicle electronics|Pipeline system
- Color:--
- Grade:Injection grade
Technical Data Sheet
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 181 °C |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | 3.2mm | UL 94 | V-0 |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dissipation factor | 1MHz | ASTM D150 | 5E-03 |
60Hz | ASTM D150 | 7E-04 | |
Dielectric constant | 1MHz | ASTM D150 | 3.47 |
60Hz | ASTM D150 | 3.48 | |
Dielectric strength | ASTM D149 | 19 KV/mm | |
Volume resistivity | ASTM D257 | 2E+16 ohms·cm |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | MD | ASTM D955 | 0.20 % |
melt mass-flow rate | 343°C/2.16kg | ASTM D1238 | 6.5 g/10min |
mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
bending strength | ASTM D790 | 154 Mpa | |
Bending modulus | ASTM D790 | 7580 Mpa | |
elongation | Break | ASTM D638 | 2.0 % |
tensile strength | ASTM D638 | 108 Mpa | |
Tensile modulus | ASTM D638 | 8690 Mpa |
impact performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ASTM D1822 | 113 kJ/m² |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.