PBT Crastin® 6129 NC010 DuPont, European Union
54
- Unit Price:US$ 3,913 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:10MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:Flame retardant|Glass fiber reinforced
- Application Areas:Electronic and electrical components|Automotive Applications|Non specific food applications
- Color:--
- Grade:Flame retardant grade
Material Certification

Technical Data Sheet
mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Elongation at Break | 23°C | ISO 527-2 | >50 % |
tensile strength | 23°C | ISO 527-2 | 58.0 Mpa |
Tensile modulus | 23°C | ISO 527-2 | 2600 Mpa |
Tensile creep modulus | 1Hr | ISO 899-1 | 2600 Mpa |
1000Hr | ISO 899-1 | 1800 Mpa | |
bending strength | 23°C | ISO 178 | 85.0 Mpa |
Bending modulus | 23°C | ISO 178 | 2350 Mpa |
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 5.5 kJ/m² |
-30°C | ISO 179/1eA | 4.0 kJ/m² | |
Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 4.5 kJ/m² |
-30°C | ISO 180/1A | 6.0 kJ/m² |
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Linear coefficient of thermal expansion | TD | ISO 11359-2 | 1.3E-04 cm/cm/°C |
MD | ISO 11359-2 | 1.3E-04 cm/cm/°C | |
Vicat softening temperature | Melting Temperature | ISO 11357-3 | 225 °C |
ISO 306/B50 | 175 °C | ||
Hot deformation temperature | 1.80MPaAnnealed | ISO 75-2/Af | 50.0 °C |
1.80MPaAnnealed | ISO 75-2/A | 60.0 °C | |
0.45MPaUnannealed | ISO 75-2/Bf | 115 °C | |
0.45MPaAnnealed | ISO 75-2/B | 180 °C |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | TD2.0mm | ISO 294-4 | 1.7 % |
MD2.0mm | ISO 294-4 | 1.5 % | |
density | ISO 1183 | 1.30 g/cm³ |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dissipation factor | 相对漏电起痕指数 | IEC 60112 | 600 V |
Dielectric strength | IEC 60243-1 | 26 KV/mm | |
Surface resistivity | IEC 60093 | 1E+12 Ω.cm | |
Volume resistivity | IEC 60093 | >1.0E+15 Ω.cm |
flame retardant performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Relative temperature of heating wire | 0.92mm | IEC 60695-2-13 | 925 °C |
Ignition temperature of heating wire | 3.00mm | IEC 60695-2-12 | 825 °C |
1.50mm | IEC 60695-2-12 | 825 °C | |
0.92mm | IEC 60695-2-12 | 825 °C | |
Extreme Oxygen Index | ISO 4589-2 | 22 % | |
UL flame retardant rating | UL -94 | HB 3.00mm | |
UL -94 | HB 1.50mm | ||
UL -94 | HB 0.92mm | ||
Relative temperature of heating wire | 1.50mm | IEC 60695-2-13 | 960 °C |
3.00mm | IEC 60695-2-13 | 850 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.