PA6 Durethan® B30SF LANXESS BELGIUM
187
- Unit Price:US$ 3,562 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:10MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:Heat aging
- Application Areas:Automotive components|Instrumentation|Electronic and electrical enclosure|Industrial applications
- Color:--
- Grade:--
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1.35 g/cm³ | |
Shrinkage rate | ISO 2577 | 1.1 % | |
ISO 2577 | 0.4 % | ||
ISO 2577 | 1.1 % | ||
ISO 2577 | 0.4 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-1-2 | 3600 Mpa | |
tensile strength | ISO 527-2/50 | 70 Mpa | |
Tensile strain | ISO 527-2/50 | 3.7 % | |
Nominal tensile fracture strain | ISO 527-2/50 | 9 % | |
Flexural modulus | ISO 178-A | 3200 Mpa | |
bending strength | ISO 178-A | 100 Mpa | |
ISO 178-A | 110 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | < 10 kJ/m² | |
ISO 179/1eA | < 10 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179/1eU | 130 kJ/m² | |
ISO 179/1eU | 150 kJ/m² | ||
Impact strength of cantilever beam gap | ISO 180-1A | < 10 kJ/m² | |
ISO 180-1A | < 10 kJ/m² | ||
Suspended wall beam without notch impact strength | ISO 180/1U | 100 kJ/m² | |
ISO 180/1U | 120 kJ/m² |
Flame retardant performance | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-0 | |
UL 94 | V-0 | ||
UL 94 | V-0 | ||
UL 94 | 5VA | ||
UL 94 | 5VA | ||
Glow wire combustion index (GWFI) | IEC 60695-2-12 | 960 °C | |
IEC 60695-2-12 | 960 °C | ||
IEC 60695-2-12 | 960 °C | ||
GWIT | IEC 60695-2-13 | 825 °C | |
IEC 60695-2-13 | 825 °C | ||
IEC 60695-2-13 | 800 °C |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | V |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-2/A | 70 °C | |
melting temperature | ISO 11357-3 | 222 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.