Material Description

  • Material Properties:Flame retardantGlass fiber reinforcedFiller: Glass fiber reinforced material15% filler by weight15% filler by weight
  • Application Areas:Electronic and electrical componentsAutomotive Applications
  • Color:--
  • Grade:Flame retardant grade

Material Certification

UL

Technical Data Sheet Compare

physical property Test ConditionTest MethodTest Result
densityISO 11831.41 g/cm³
densityISO 11831.41 g/cm³
Shrinkage rateISO 294-41.1 %
Shrinkage rateISO 294-40.40 %
Shrinkage rateISO 294-4360 mm
Ejection Temperature170 °C
flammabilityTest ConditionTest MethodTest Result
burning rateISO 379530 mm/min
UL flame retardant ratingUL 94HB
UL flame retardant ratingUL 94HB
UL flame retardant ratingIEC 60695-11-10,-20HB
UL flame retardant ratingIEC 60695-11-10,-20HB
FMVSS flammabilityFMVSS302B
Fogging-G-valueISO 64521E-04 g
Supplementary InformationTest ConditionTest MethodTest Result
Emissions of Organic CompoundsVDA277140 µgC/g
OdorVDA2703.00
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-15700 MPa
Tensile modulusISO 527-25800 Mpa
tensile strength ISO 527-2109 Mpa
Tensile strainISO 527-23.5 %
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO 179/1eA7.0 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU40 kJ/m²
Impact strength of cantilever beam gapISO 180/1A5.0 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Dissipation FactorIEC 602507E-04
Dissipation FactorIEC 602500.017
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 3
Surface ResistivityIEC 600931E+14 ohms
Volume resistivityIEC 60093>1.0E+15 ohms·cm
dielectric strengthIEC 60243-135 KV/mm
relative permittivityIEC 602503.70
relative permittivityIEC 602503.60
Thermal performanceTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94HB
UL flame retardant ratingUL 94HB
UL flame retardant ratingUL 94HB
Heat distortion temperatureISO 75-2/A200 °C
melting temperatureISO 11357-3225 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.