Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PBT SK602 WT DUPONT USA
Cristin®
Electronic and electrical components,Automotive Applications
Flame retardant,Glass fiber reinforced,Filler: Glass fiber reinf,15% filler by weight,15% filler by weight
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Supplementary Information | Test Condition | Test Method | DUPONT USA/SK602 WT |
---|---|---|---|
EmissionofOrganicCompounds | VDA277 | 140 µgC/g | |
Odor | VDA270 | 3.00 |
thermal performance | Test Condition | Test Method | DUPONT USA/SK602 WT |
---|---|---|---|
Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 200 °C |
Melting temperature | ISO 11357-3 | 225 °C | |
UL flame retardant rating | 6.00 mm | UL 94 | HB |
1.50 mm | UL 94 | HB | |
3.00 mm | UL 94 | HB |
mechanical properties | Test Condition | Test Method | DUPONT USA/SK602 WT |
---|---|---|---|
Tensile modulus | ISO 527-2 | 5800 Mpa | |
0.00 mm, 23 ℃, Injection Molded | ISO 527-1 | 5700 MPa | |
Tensile strain | Break | ISO 527-2 | 3.5 % |
tensile strength | Break | ISO 527-2 | 109 Mpa |
Electrical performance | Test Condition | Test Method | DUPONT USA/SK602 WT |
---|---|---|---|
Compared to the anti leakage trace index | IEC 60112 | PLC 3 | |
Dielectric strength | IEC 60243-1 | 35 KV/mm | |
Dissipation factor | 1MHz | IEC 60250 | 0.017 |
100Hz | IEC 60250 | 7E-04 | |
Relative permittivity | 100Hz | IEC 60250 | 3.70 |
1MHz | IEC 60250 | 3.60 | |
Surface resistivity | IEC 60093 | 1E+14 ohms | |
Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm |
Physical properties | Test Condition | Test Method | DUPONT USA/SK602 WT |
---|---|---|---|
density | ISO 1183 | 1.41 g/cm³ | |
Shrinkage rate | MD | ISO 294-4 | 0.40 % |
MDLength2(2.00mm) | ISO 294-4 | 360 mm | |
TD | ISO 294-4 | 1.1 % | |
Top out temperature | 170 °C |
impact performance | Test Condition | Test Method | DUPONT USA/SK602 WT |
---|---|---|---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 7.0 kJ/m² |
Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 5.0 kJ/m² |
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 40 kJ/m² |
flammability | Test Condition | Test Method | DUPONT USA/SK602 WT |
---|---|---|---|
Burning rate | 1.00mm | ISO 3795 | 30 mm/min |
FMVSS flammability | FMVSS302 | B | |
Fogging-G-value | condensate | ISO 6452 | 1E-04 g |
UL flame retardant rating | 3.0mm | IEC 60695-11-10,-20 | HB |
3.0mm | UL 94 | HB | |
1.5mm | IEC 60695-11-10,-20 | HB | |
1.5mm | UL 94 | HB |