PEEK VICTREX® 90GL30 VICTREX UK
199
- Unit Price:US$ 84,798 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:10.1MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:--
- Application Areas:--
- Color:--
- Grade:Injection grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
spiral flow length | 内部方法 | 18.5 CM | |
内部方法 | 22.0 CM | ||
Shrinkage rate | ISO 294-4 | 0.90 % | |
ISO 294-4 | 0.30 % | ||
Water absorption rate | ISO 62 | 0.30 % | |
ISO 62 | 0.450 % |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Shore hardness | ISO 868 | 87 |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
Burning wire flammability index | IEC 60695-2-12 | 960 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2 | 12000 Mpa | |
bending strength | ISO 178 | 75.0 Mpa | |
compression stress | ISO 604 | 250 Mpa | |
ISO 604 | 160 Mpa | ||
ISO 604 | 55.0 Mpa | ||
tensile strength | ISO 527-2 | 195 Mpa | |
ISO 527-2 | 130 Mpa | ||
ISO 527-2 | 80.0 Mpa | ||
ISO 527-2 | 60.0 Mpa | ||
ISO 527-2 | 45.0 Mpa | ||
Tensile strain | ISO 527-2 | 2.4 % | |
Flexural modulus | ISO 178 | 11500 Mpa | |
bending strength | ISO 178 | 290 Mpa | |
ISO 178 | 230 Mpa | ||
ISO 178 | 115 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179/1U | 45 kJ/m² | |
Suspended wall beam without notch impact strength | ISO 180 | 45 kJ/m² |
Filling analysis | Test Condition | Test Method | Test Result |
---|---|---|---|
melt viscosity | ISO 11443 | 200 Pa·s |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dissipation Factor | IEC 60250 | 4E-03 | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | V | |
Volume resistivity | IEC 60093 | 1E+16 ohms·cm | |
dielectric strength | IEC 60243-1 | 23 KV/mm | |
dielectric constant | IEC 60250 | 3.30 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-2/Af | 335 °C | |
Glass Transition Temperature | ISO 11357 | 143 °C | |
melting temperature | ISO 11357-3 | 343 °C | |
Linear coefficient of thermal expansion | ISO 11359-2 | 2E-05 cm/cm/°C | |
ISO 11359-2 | 2E-05 cm/cm/°C | ||
ISO 11359-2 | 4.5E-05 cm/cm/°C | ||
ISO 11359-2 | 1.1E-04 cm/cm/°C | ||
thermal conductivity | ISO 22007-4 | 0.30 W/m/K | |
ISO 22007-4 | 0.35 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App
Top