LCP LAPEROS® A130 BK025P DAICEL MALAYSIA
174
- Unit Price:US$ 8,721 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:50MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:Flame retardant|Glass fiber reinforced|Thermal stability|Chemical resistance
- Application Areas:Electrical field|Electronic field|Household appliances|Household appliances
- Color:--
- Grade:Extrusion grade
Material Certification

Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ISO 294-4 | 0.40 % | |
ISO 294-4 | 0.20 % | ||
Water absorption rate | ISO 62 | 0.040 % |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Rockwell hardness | ISO 2039-2 | 85 |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-0 | |
Limiting Oxygen Index | ISO 4589-2 | 45 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2/1A | 15000 Mpa | |
tensile strength | ISO 527-2/1A/5 | 190 Mpa | |
Tensile strain | ISO 527-2/1A/5 | 2.1 % | |
Tensile creep modulus | ISO 899-1 | 12600 Mpa | |
ISO 899-1 | 10900 Mpa | ||
Flexural modulus | ISO 178 | 14500 Mpa | |
bending strength | ISO 178 | 280 Mpa | |
Compression Modulus | ISO 604 | 14500 Mpa | |
compression stress | ISO 604 | 100 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Suspended wall beam without notch impact strength | ISO 180/1U | 29 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | IEC 60093 | > 1.0E+15 ohms | |
Volume resistivity | IEC 60093 | 1.0E+15 ohms·cm | |
dielectric strength | IEC 60243-1 | 31 KV/mm | |
relative permittivity | IEC 60250 | 4.20 | |
IEC 60250 | 3.70 | ||
Dissipation Factor | IEC 60250 | 0.016 | |
IEC 60250 | 0.018 | ||
arc resistance | 内部方法 | 140 sec | |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 3 |
injection | Test Condition | Test Method | Test Result |
---|---|---|---|
drying temperature | 150 °C | ||
drying time | 4.0 to 6.0 hr | ||
Suggested maximum moisture content | 0.010 % | ||
Hopper temperature | 20 to 30 °C | ||
Temperature at the rear of the barrel | 270 to 280 °C | ||
Temperature in the middle of the barrel | 275 to 285 °C | ||
Temperature at the front of the material cylinder | 280 to 290 °C | ||
Spray nozzle temperature | 290 to 300 °C | ||
Processing (melt) temperature | 285 to 295 °C | ||
Temperature | 80 to 120 °C | ||
injection speed | 快速 | ||
Back pressure | < 3.00 Mpa |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-2/B | 250 °C | |
ISO 75-2/A | 235 °C | ||
ISO 75-2/C | 190 °C | ||
vicat | ISO 306/B50 | 160 °C | |
melting temperature | ISO 11357-3 | 280 °C | |
Linear coefficient of thermal expansion | ISO 11359-2 | 6.0E-6 cm/cm/°C | |
ISO 11359-2 | 2.3E-5 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.