PA66 TECHNYL® A218 S30 SOLVAY FRANCE
319
- Unit Price:US$ 4,410 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:40.8MT
- Delivery Terms:FOB
- Port of Loading :Shenzhen Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:--
- Application Areas:--
- Color:--
- Grade:--
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 25 kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Extreme Oxygen Index | ISO 4589-2 | 25 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | 23°C | ISO 178 | 3850 | Mpa |
| Tensile strain | Break, 23°C | ISO 527-2 | 7.0 | % |
| tensile strength | Break, 23°C | ISO 527-2/1A | 80.0 | Mpa |
| Tensile modulus | 23°C | ISO 527-2/1A | 4500 | Mpa |
| injection | Test Condition | Test Method | Test Result | Test Unit |
| Mold temperature | 70 to 100 | °C | ||
| Temperature at the front of the material cylinder | 280 to 290 | °C | ||
| Temperature in the middle of the barrel | 275 to 285 | °C | ||
| Temperature at the rear of the barrel | 270 to 280 | °C | ||
| Suggested maximum moisture content | 0.20 | % | ||
| drying temperature | 80 | °C | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 11357-3 | 263 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 1.6 | % |
| 24 hr, 23°C | ISO 62 | 0.75 | % | |
| Shrinkage rate | Flow | ISO 294-4 | 1.1 | % |
| 横向Flow | ISO 294-4 | 1.1 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | Solution A | IEC 60112 | PLC 1 | |
| Dissipation factor | IEC 60250 | 0.020 | ||
| Dielectric strength | 2.00 mm | IEC 60243-1 | 30 | KV/mm |
| Volume resistivity | IEC 60093 | 5.0E+14 | ohms·cm | |
| Surface resistivity | IEC 60093 | 5.0E+14 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.