PC PANLITE® GN-3620L TEIJIN JAPAN
305
- Unit Price:US$ 3,830 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:34MT
- Delivery Terms:FOB
- Port of Loading :Shenzhen Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:High rigidity|Glass fiber reinforced
- Application Areas:Industrial applications|Electrical components
- Color:--
- Grade:--
Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| remarks | 以上加工数据.为参考值.以生产厂商设备的实际状况而进行调整。 | |||
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of simply supported beam without notch | ISO 179 | 40 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.40mm | UL 94 | V-2 | |
| 1.0mm | UL 94 | V-1 | ||
| 1.6mm | UL 94 | V-0 | ||
| Burning wire flammability index | 1.0mm | IEC 60695-2-12 | 960 | °C |
| 1.6mm | IEC 60695-2-12 | 960 | °C | |
| 3.0mm | IEC 60695-2-12 | 960 | °C | |
| Hot filament ignition temperature | 1.0mm | IEC 60695-2-13 | 825 | °C |
| 1.6mm | IEC 60695-2-13 | 850 | °C | |
| 3.0mm | IEC 60695-2-13 | 850 | °C | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Elongation at Break | ASTM D638/ISO 527 | 1.0 | % | |
| bending strength | ASTM D790/ISO 178 | 138 | kg/cm²(MPa)[Lb/in²] | |
| Bending modulus | ASTM D790/ISO 178 | 5600 | kg/cm²(MPa)[Lb/in²] | |
| tensile strength | ASTM D638/ISO 527 | 82.0 | kg/cm²(MPa)[Lb/in²] | |
| Tensile modulus | ASTM D638/ISO 527 | 6100 | kg/cm²(MPa)[Lb/in²] | |
| ISO 527-2/1 | 6100 | Mpa | ||
| tensile strength | Break | ISO 527-2/5 | 82.0 | Mpa |
| Tensile strain | Break | ISO 527-2/5 | 1.0 | % |
| Bending modulus | ISO 178 | 5600 | Mpa | |
| bending strength | ISO 178 | 138 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Str | 1.5mm | UL 746 | 80.0 | °C |
| RTI Imp | 1.5mm | UL 746 | 80.0 | °C |
| RTI Elec | 1.5mm | UL 746 | 80.0 | °C |
| Linear coefficient of thermal expansion | TD | ISO 11359-2 | 6E-05 | cm/cm/°C |
| MD | ISO 11359-2 | 3E-05 | cm/cm/°C | |
| Vicat softening temperature | ISO 306/B50 | 147 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 140 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 145 | °C | |
| Linear coefficient of thermal expansion | ASTM D696/ISO 11359 | 0.000030 | mm/mm.℃ | |
| Vicat softening temperature | ASTM D1525/ISO R306 | 147 | ℃(℉) | |
| Hot deformation temperature | HDT | ASTM D648/ISO 75 | 145 | ℃(℉) |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | ASTM D570/ISO 62 | 0.14 | % | |
| Shrinkage rate | ASTM D955 | 0.40-0.60 | % | |
| TD:4.00mm | Internal Method | 0.40-0.60 | % | |
| MD:4.00mm | Internal Method | 0.10-0.30 | % | |
| Water absorption rate | 23°C,24hr | ISO 62 | 0.14 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric loss | ASTM D150/IEC 60250 | 0.0090 | ||
| ASTM D150/IEC 60250 | 0.0010 | |||
| Volume resistivity | ASTM D257/IEC 60093 | 1.0E+15 | Ω.cm | |
| Dielectric constant | ASTM D150/IEC 60250 | 3.40 | ||
| Surface resistivity | ASTM D257/IEC 60093 | 1.0E+15 | Ω | |
| IEC 60093 | >1.0E+15 | ohms | ||
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Dielectric strength | IEC 60243-1 | 35 | KV/mm | |
| Dielectric constant | 100Hz | IEC 60250 | 3.40 | |
| 1MHz | IEC 60250 | 3.40 | ||
| Dissipation factor | 100Hz | IEC 60250 | 1E-03 | |
| 1MHz | IEC 60250 | 9E-03 | ||
| Compared to the anti leakage trace index | IEC 60112 | PLC 3 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.