PA6 Durethan® BKV315ZH2.0 901510 LANXESS GERMANY
200
- Unit Price:US$ 2,785 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:78.5MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:--
- Application Areas:--
- Color:--
- Grade:Injection grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Apparent density | ISO 60 | 0.70 g/cm³ | |
Shrinkage rate | ISO 294-4 | 0.60 % | |
ISO 294-4 | 0.10 % | ||
ISO 294-4 | 0.90 % | ||
ISO 294-4 | 0.20 % |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
ball-indentation hardness | ISO 2039-1 | 140 Mpa |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | HB | |
UL 94 | HB | ||
Burning Behavior | ISO 3795 | passed |
Supplementary Information | Test Condition | Test Method | Test Result |
---|---|---|---|
ISO Shortcut | ISO 1874 | PA6-HI.BHR.14-050.GF15 |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179/1eU | 80 kJ/m² | |
Suspended wall beam without notch impact strength | ISO 180/1U | 70 kJ/m² | |
ISO 180/1U | 65 kJ/m² | ||
Impact strength of simply supported beam without notch | ISO 179/1eU | 85 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2/1 | 5300 Mpa | |
tensile strength | ISO 527-2/5 | 105 Mpa | |
Tensile strain | ISO 527-2/5 | 5.0 % | |
Flexural modulus | ISO 178/A | 4800 Mpa | |
bending strength | ISO 178/A | 150 Mpa | |
ISO 178 | 165 Mpa | ||
5.5 % |
film | Test Condition | Test Method | Test Result |
---|---|---|---|
Thin film puncture strength | ISO 6603-2 | 2.50 J | |
ISO 6603-2 | 4.90 J | ||
ISO 6603-2 | 630 N | ||
ISO 6603-2 | 1200 N |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 2 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ISO 75-2/B | 210 °C | |
ISO 75-2/A | 175 °C | ||
ISO 75-2/C | 58.0 °C | ||
melting temperature | ISO 11357-3 | 221 °C | |
Linear coefficient of thermal expansion | ISO 11359-2 | 4E-05 cm/cm/°C | |
ISO 11359-2 | 1.3E-04 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.