ABS CYCOLAC™ FR15U SABIC INNOVATIVE US
288
- Unit Price:US$ 6,732 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:55MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:Flame retardant|UV resistance
- Application Areas:Automotive sector|Electronic field|Electrical field
- Color:--
- Grade:Injection grade
Material Certification

Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
MeltViscosity | ASTM D3835 | 320 Pa·s | |
density | ASTM D792 | 1.19 g/cm³ | |
ISO 1183 | 1.19 g/cm³ | ||
melt mass-flow rate | ASTM D1238 | 3.3 g/10min | |
ISO 1133 | 7.0 g/10min | ||
Melt volume flow rate | ISO 1133 | 40.0 cm3/10min | |
Shrinkage rate | 内部方法 | 0.50-0.70 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | V-0 | |
UL 94 | 5VA |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dart impact | ASTM D3763 | 28.5 J | |
Impact strength of cantilever beam gap | ASTM D256 | 210 J/m | |
ISO 180/1A | 12 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | ASTM D638 | 30.3 Mpa | |
elongation | ASTM D638 | 2.4 % | |
ASTM D638 | 17 % | ||
Tensile strain | ISO 527-2/50 | 22 % | |
Flexural modulus | ASTM D790 | 2340 Mpa | |
ISO 178 | 2260 Mpa | ||
bending strength | ISO 178 | 63.3 Mpa | |
ASTM D790 | 67.6 Mpa | ||
Tensile modulus | ASTM D638 | 2070 Mpa | |
ISO 527-2/1 | 2210 Mpa | ||
tensile strength | ASTM D638 | 37.9 Mpa | |
ISO 527-2/50 | 41.1 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | IEC 60093 | >1.0E+14 ohms·cm | |
dielectric strength | IEC 60243-1 | 20 KV/mm | |
arc resistance | ASTM D495 | PLC7 | |
Compared to the Leakage Tracking Index (CTI) | UL 746 | PLC 1 | |
High arc combustion index (HAI) | UL 746 | PLC 4 | |
High Voltage Arc Traceability Rate (HVTR) | UL 746 | PLC 4 | |
Hot wire ignition (HWI) | UL 746 | PLC 2 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648 | 86.1 °C | |
ASTM D648 | 75.0 °C | ||
vicat | ASTM D15258 | 93.9 °C | |
ISO 306/B50 | 92.0 °C | ||
Linear coefficient of thermal expansion | ASTME831 | 9E-05 cm/cm/°C | |
ASTME831 | 9.2E-05 cm/cm/°C | ||
RTI Elec | UL 746 | 90.0 °C | |
RTI Imp | UL 746 | 85.0 °C | |
RTI Str | UL 746 | 90.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.