plas

PBT VALOX™  310SEO-1001 SABIC INNOVATIVE THAILAND

246
  • Unit Price:US$ 3,240 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    33MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View

For more details, please contact the supplier!

Material Description

  • Material Properties:Flame retardant
  • Application Areas:Industrial applicationsElectrical fieldElectronic fieldSwitch panelShell
  • Color:--
  • Grade:Injection grade

Material Certification

UL

Technical Data Sheet

impact performanceTest ConditionTest MethodTest Result
Impact strength of simply supported beam without notch-30°CISO 179/1eU无断裂
Impact strength of simply supported beam without notch23°CISO 179/1eU无断裂
Suspended wall beam without notch impact strength23°CASTM D4812无断裂
Suspended wall beam without notch impact strength-30°C9ISO 180/1U无断裂
Dart impact23°C, Total EnergyASTM D3763200 J
flammabilityTest ConditionTest MethodTest Result
UL flame retardant rating0.71 mmUL 94V-0
UL flame retardant rating3.0 mmUL 945VA
Burning wire flammability index1.0 mmIEC 60695-2-12960 °C
Extreme Oxygen IndexISO 4589-230 %
mechanical propertiesTest ConditionTest MethodTest Result
Bending modulus50.0 mm Span5ASTM D7902620 Mpa
elongationBreakISO 527-2/5018 %
elongationBreak4ASTM D63818 %
elongationYieldISO 527-2/505.0 %
elongationYield4ASTM D6385.0 %
tensile strengthBreakISO 527-2/5040.0 Mpa
tensile strengthBreak4ASTM D63852.0 Mpa
tensile strengthYieldISO 527-2/5058.0 Mpa
tensile strengthYield4ASTM D63858.0 Mpa
Tensile modulus--ISO 527-2/12800 Mpa
Tensile modulus--3ASTM D6382820 Mpa
Bending modulus--6ISO 1782600 Mpa
bending strength--6,7ISO 17890.0 Mpa
bending strengthYield, 50.0 mm Span5ASTM D790101 Mpa
Taber abraser1000 Cycles, 1000 g, CS-17 WheelInternal Method19.0 mg
injectionTest ConditionTest MethodTest Result
drying temperature120 °C
drying time3.0 to 4.0 hr
Suggested maximum moisture content0.020 %
Suggested injection volume40 to 80 %
Temperature at the rear of the barrel230 to 250 °C
Temperature in the middle of the barrel240 to 255 °C
Temperature at the front of the material cylinder245 to 260 °C
Spray nozzle temperature240 to 255 °C
Screw speed50 to 100 rpm
Exhaust hole depth0.013 to 0.025 mm
Processing (melt) temperature245 to 260 °C
Mold temperature50 to 75 °C
Back pressure0.300 to 0.700 Mpa
thermal performanceTest ConditionTest MethodTest Result
Hot deformation temperature0.45 MPa, Unannealed, 6.40 mmASTM D648162 °C
Hot deformation temperature0.45 MPa, Unannealed, 4.00 mm, 100 mm Span10ISO 75-2/Be150 °C
Hot deformation temperature1.8 MPa, Unannealed, 3.20 mmASTM D64874.0 °C
Hot deformation temperature1.8 MPa, Unannealed, 6.40 mmASTM D64871.0 °C
Hot deformation temperature1.8 MPa, Unannealed, 4.00 mm, 100 mm Span10ISO 75-2/Ae60.0 °C
Hot deformation temperature1.8 MPa, Unannealed, 4.00 mm, 64.0 mm Span9ISO 75-2/Af73.0 °C
Vicat softening temperature--ASTM D152511170 °C
Vicat softening temperature--ISO 306/A50212 °C
Ball Pressure Test123 to 127°CIEC 60695-10-2通过
Linear coefficient of thermal expansionFlow : -40 to 40°CASTM E8317.9E-5 cm/cm/°C
thermal conductivityISO 83020.24 W/m/K
Linear coefficient of thermal expansionFlow : 60 to 138°CASTM E8311.3E-4 cm/cm/°C
Linear coefficient of thermal expansionFlow : -40 to 40°CISO 11359-27.6E-5 cm/cm/°C
Linear coefficient of thermal expansionFlow : 23 to 60°CISO 11359-21.0E-4 cm/cm/°C
Linear coefficient of thermal expansionAcross Flow : -40 to 40°CASTM E8317.9E-5 cm/cm/°C
Linear coefficient of thermal expansionAcross Flow : -40°CISO 11359-27.3E-5 cm/cm/°C
Linear coefficient of thermal expansionAcross Flow : 23 to 60°CISO 11359-21.0E-4 cm/cm/°C
RTI ElecUL 746120 °C
RTI ImpUL 746120 °C
RTIUL 746140 °C
Physical propertiesTest ConditionTest MethodTest Result
Water absorption rateEquilibrium, 23°C, 50% RHISO 620.080 %
Water absorption rateSaturation, 23°CISO 620.36 %
Shrinkage rateAcross FlowFlow : 2.30 to 4.60 mmInternal Method1.6 - 2.4 %
Shrinkage rateAcross FlowFlow : 0.750 to 2.30 mmInternal Method1.0 - 1.7 %
Shrinkage rateAcross FlowFlow 2Internal Method0.90 - 1.9 %
Shrinkage rateFlow : 2.30 to 4.60 mmInternal Method1.5 - 2.3 %
Shrinkage rateFlow : 3.20 mmInternal Method1.5 - 2.3 %
Shrinkage rateFlow : 0.750 to 2.30 mmInternal Method0.90 - 1.6 %
Shrinkage rateFlow 2Internal Method1.1 - 1.8 %
Melt Volume Flow Rate (MVR)250°C/2.16 kgISO 11338.00 cm3/10min
melt mass-flow rate250°C/2.16 kgASTM D12388.6 g/10 min
Specific volumeASTM D7920.710 cm³/g
Electrical performanceTest ConditionTest MethodTest Result
Dissipation factor1 MHzIEC 602500.013
Hot wire ignitionUL 746PLC 2
Surface resistivityIEC 60093> 1.0E+15 ohms
Volume resistivityIEC 60093> 1.0E+15 ohms·cm
Dielectric strength1.60 mm, in OilASTM D14924 KV/mm
Dielectric strength3.20 mm, in AirASTM D14918 KV/mm
Dielectric strength0.800 mm, in OilIEC 60243-135 KV/mm
Dielectric strength1.00 mm12IEC 60243-118 KV/mm
Dielectric strength1.60 mm, in OilIEC 60243-125 KV/mm
Dielectric strength3.20 mm, in OilIEC 60243-117 KV/mm
Relative permittivity50 HzIEC 602502.90
Relative permittivity60 HzIEC 602502.90
Relative permittivity100 HzIEC 602503.10
Relative permittivity1 MHzIEC 602502.80
Dissipation factor50 HzIEC 602501.0E-3
Dissipation factor60 HzIEC 602501.0E-3
Dissipation factor100 HzIEC 602502.0E-3
Arc resistanceASTM D495PLC 6
Compared to the anti leakage trace indexUL 746PLC 3
Compared to the anti leakage trace index--IEC 60112PLC 3
High voltage arc tracing rateUL 746PLC 4
Compared to the anti leakage trace indexSolution BIEC 60112PLC 4
High arc combustion indexUL 746PLC 0
High Voltage Arc Resistance Index (HVAR) (PLC)UL 746PLC 6
hardnessTest ConditionTest MethodTest Result
Ball Pressure TestH 358/30ISO 2039-1105 Mpa
Rockwell hardnessR -SaleISO 2039-2120
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.