GPPS Bycolene® 147F BASF KOREA
172
- Unit Price:US$ 1,686 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:15MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:Easy to process|Good heat resistance|Moderate liquidity|Universal type with good dimensional stability
- Application Areas:Transparent parts of refrigerator|Household daily necessities|chip|Monitor
- Color:--
- Grade:Injection grade
Material Certification
TDS
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1046 kg/m3 | |
Water absorption rate | ISO 62 | <0.1 % | |
ISO 62 | <0.1 % |
processability | Test Condition | Test Method | Test Result |
---|---|---|---|
Linear mold shrinkage rate | ISO 294-4 | 0.3 - 0.6 % | |
Melting temperature range | ISO 294 | 180 - 260 ℃ | |
Mold temperature range | ISO 294 | 10 - 60 ℃ | |
Injection Speed | ISO 294 | 200 mm/s |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Melt volume flow rate | ISO 1133 | 6.5 cm3/10min | |
Charpy Notched Impact Strength | ISO 179 | 3 kJ/m² | |
Impact strength of simply supported beam without notch | ISO 179 | 17 kJ/m² | |
tensile yield strength | ISO 527 | 50 Mpa | |
tensile elongation at break | ISO 527 | 3 % | |
Tensile modulus | ISO 527 | 3300 Mpa | |
bending strength | ISO 178 | 98 Mpa | |
ball-indentation hardness | ISO 2039-1 | 150 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
breakdown voltage | IEC 60243-1 | 135 KV/mm | |
dielectric constant | IEC 60250 | 2.5 - | |
IEC 60250 | 2.5 - | ||
Volume resistivity | IEC 60093 | >1E16 ohm·m | |
Surface Resistivity | IEC 60093 | >1E14 Ohm |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
vicat | ISO 306 | 95 ℃ | |
ISO 306 | 100 ℃ | ||
Heat distortion temperature | ISO 75 | 85 ℃ | |
ISO 75 | 93 ℃ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.