Impact strength of simply supported beam without notch
23℃23℃
ISO 179
28 kJ/m²
Impact strength of cantilever beam gap
23℃23℃
ISO 180
9 kJ/m²
Suspended wall beam without notch impact strength
23℃23℃
ISO 180
29 kJ/m²
mechanical properties
شرایط آزمون
روش آزمون
نتیجه آزمون
Tensile modulus
ISO 527-2
10600 Mpa
tensile strength
BreakBreak
ISO 527-2
115 Mpa
Tensile strain
BreakBreak
ISO 527-2
1.6 %
Bending modulus
ISO 178
10000 Mpa
bending strength
ISO 178
170 Mpa
thermal performance
شرایط آزمون
روش آزمون
نتیجه آزمون
Hot deformation temperature
1.8 MPa,Unannealed1.8 MPa,Unannealed
ISO 75-2/A
245 °C
Hot deformation temperature
0.45 MPa,Unannealed
ISO 75-2/B
265 °C
Linear coefficient of thermal expansion
TD:-30~30℃TD:-30 to 30℃
TMA
0.000040 1/℃
Linear coefficient of thermal expansion
MD:-30~30℃MD:-30 to 30℃
TMA
0.000020 1/℃
Relative Heat Index (RTI)
电气性能
UL 746
50 °C
Relative Heat Index (RTI)
强度机械性能
UL 746
50 °C
Relative Heat Index (RTI)
冲击机械性能
UL 746
50 °C
Physical properties
شرایط آزمون
روش آزمون
نتیجه آزمون
density
ISO 1183
1.42 g/cm³
Shrinkage rate
TDAcross Flow
Internal Method
0.50 - 0.80 %
Shrinkage rate
MDFlow
Internal Method
0.10 - 0.40 %
Water absorption rate
Equilibrium,23℃,50% RHEquilibrium,23℃,50% RH2
ISO 62
0.02 %
Electrical performance
شرایط آزمون
روش آزمون
نتیجه آزمون
Volume resistivity
IEC 60093
> 1.0E+16 ohms·cm
Dielectric strength
ASTM D149
35 KV/mm
Dielectric constant
1 MHz1 MHz
IEC 60250
3
Dissipation factor
1 MHz1 MHz
IEC 60250
0.002
Arc resistance
ASTM D495
PLC 6
Compared to the anti leakage trace index
IEC 60112
PLC 0
flame retardant performance
شرایط آزمون
روش آزمون
نتیجه آزمون
> 1.50 mm> 1.5 mm
UL 94
V-0