physical property | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
Apparent density | | ISO 60 | 0.70 g/cm³ |
Shrinkage rate | TD:280°C,3.00mm2 | ISO 2577 | 1.5 % |
Shrinkage rate | TD:120°C,2hr,3.00mm3 | ISO 294-4 | 0.050 % |
Shrinkage rate | MD:280°C,3.00mm2 | ISO 2577 | 0.35 % |
Shrinkage rate | MD:120°C,2hr,3.00mm3 | ISO 2577 | 0.040 % |
Water absorption rate | 饱和,23°C | ISO 62 | 5.5 % |
Water absorption rate | 平衡,23°C,50%RH | ISO 62 | 2.0 % |
hardness | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
ball-indentation hardness | | ISO 2039-1 | 230 Mpa |
other | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
notes | | | 30%玻纤增强.热稳定级 |
processability | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
Temperature | | | 80 °C |
Melt Temperature | | | 290 °C |
flammability | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
UL flame retardant rating | 1.6mm | UL 94 | HB |
UL flame retardant rating | 3.2mm | UL 94 | HB |
Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 600 °C |
Limiting Oxygen Index | | ISO 4589-2 | 23 % |
Supplementary Information | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
ISO Shortcut | | ISO 1874 | PA66.GR.14-110.GF30 |
Mechanical properties | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
Tensile modulus | | ASTM D638/ISO 527 | 10600-7000 kg/cm²(MPa)[Lb/in²] |
tensile strength | | ASTM D638/ISO 527 | 185-120 kg/cm²(MPa)[Lb/in²] |
Flexural modulus | | ASTM D790/ISO 178 | 8400-5900 kg·cm/cm(J/M)ft·lb/in |
bending strength | | ASTM D790/ISO 178 | 290-200 kg·cm/cm(J/M)ft·lb/in |
elongation at break | | ASTM D638/ISO 527 | 3.0-6.0 % |
tensile strength | 断裂,23°C | ASTM D638 | 179 Mpa |
tensile strength | 断裂,23°C | ISO 527-2/5 | 185 Mpa |
elongation | 断裂,23°C | ASTM D638 | 3.0 % |
Tensile strain | 断裂,23°C | ISO 527-2/5 | 3.0 % |
Flexural modulus | 23°C | ASTM D790 | 841 Mpa |
Flexural modulus | 23°C | ISO 178/A | 8400 Mpa |
bending strength | 23°C | ASTM D790 | 290 Mpa |
bending strength | 3.5%Strain | ISO 178/A | -- Mpa |
bending strength | 23°C | ISO 178 | 290 Mpa |
bending strength | FlexuralStrainatFlexuralStrength5(23°C) | | 4.0 % |
Tensile modulus | 23°C | ASTM D638 | 10300 Mpa |
Tensile modulus | 23°C | ISO 527-2/1 | 10600 Mpa |
Impact resistance | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 70 kJ/m² |
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 90 kJ/m² |
Electrical performance | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
Surface Resistivity | | ASTM D257/IEC 60093 | 10 14(10 13) Ω |
arc resistance | | ASTM D495/IEC 60112 | 40(35) |
Volume resistivity | | ASTM D257/IEC 60093 | 10 13(10 11) Ω.cm |
Surface Resistivity | | IEC 60093 | 1E+14 ohms |
Volume resistivity | 23°C | IEC 60093 | 1E+15 ohms·cm |
dielectric strength | 23°C,1.00mm | IEC 60243-1 | 40 KV/mm |
relative permittivity | 23°C,100Hz | IEC 60250 | 4.00 |
relative permittivity | 23°C,1MHz | IEC 60250 | 4.00 |
Dissipation Factor | 23°C,100Hz | IEC 60250 | 9E-03 |
Dissipation Factor | 23°C,1MHz | IEC 60250 | 0.018 |
Compared to the Leakage Tracking Index (CTI) | 解决方案A | IEC 60112 | PLC 0 |
Physical properties | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
Shrinkage rate | | ASTM D955 | 0.353) % |
Thermal performance | شرایط آزمون | روش آزمون | نتیجه آزمون |
---|
Heat distortion temperature | HDT | ASTM D648/ISO 75 | 1.36 ℃(℉) |
melting temperature | | | 263 ℃(℉) |
vicat | | ASTM D1525/ISO R306 | >230 ℃(℉) |
vicat | | ISO 306/B120 | >230 °C |
melting temperature | | ISO 11357-3 | 263 °C |
Linear coefficient of thermal expansion | MD:23到55°C | ISO 11359-2 | 2.5E-05 cm/cm/°C |
Linear coefficient of thermal expansion | TD:23to55°C | ISO 11359-2 | 1E-04 cm/cm/°C |
Heat distortion temperature | 0.45MPa,未退火,HDT | ISO 75-2/B | 250 °C |
Heat distortion temperature | 1.8MPa,未退火,HDT | ISO 75-2/A | 250 °C |
Heat distortion temperature | 8.0MPa,未退火,HDT | ISO 75-2/C | 135 °C |