Share
Add to compare

PBT HR5330HF-NC010 DUPONT USA

42

Form:Granules | Grade:Injection grade

Properties:
Hydrolysis resistanceGlass fiber reinforcedFiller: Glass fiber reinf30% filler by weight
Typical Applications:
Electronic and electrical components
Product Description
Certificates(1)
Datasheet

Product Description

Typical Applications:Electronic and electrical components
Properties:Hydrolysis resistance | Glass fiber reinforced | Filler: Glass fiber reinf | 30% filler by weight

Certificates

UL
UL

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of cantilever beam gap23°CISO 180/1A14kJ/m²
Impact strength of cantilever beam gap-40°CISO 180/1A11kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU70kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA13kJ/m²
Charpy Notched Impact Strength-30°CISO 179/1eA12kJ/m²
Suspended wall beam without notch impact strength23°CISO 180/1U65kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
Burning rate1.00mmISO 379530mm/min
UL flame retardant rating0.75mmUL 94HB
Flammability level0.75mmIEC 60695-11-10,-20HB
Extreme Oxygen IndexISO 4589-219%
FMVSS flammabilityFMVSS302B
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Poisson's ratioISO 5270.34
bending strengthISO 178200Mpa
Bending modulusISO 1787700Mpa
Tensile strainBreakISO 527-23.5%
tensile strengthBreakISO 527-2132Mpa
Impact strength of cantilever beam gap23 ℃, Type 1, Notch AISO 18016.3KJ/m
Impact strength of cantilever beam gap-40 ℃, Type 1, Notch AISO 18011.1KJ/m
Charpy Notched Impact Strength23 ℃, Type 1, Edgewise, Notch AISO 17914.9KJ/m
Charpy Notched Impact Strength-30 ℃, Type 1, Edgewise, Notch AISO 17911.5KJ/m
Impact strength of simply supported beam without notch23 ℃, Type 1, EdgewiseISO 17975.1KJ/m
bending strength23℃ISO 178203MPa
Bending modulus23℃ISO 1787800MPa
Tensile modulus23℃ISO 527-18500MPa
elongation23℃,YieldISO 527-13.5%
Tensile stress23℃,YieldISO 527-1134MPa
Tensile modulusISO 527-28500Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.80 Mpa,UnannealedISO 75B-1207
Hot deformation temperature0.45 Mpa,UnannealedISO 75B-1221
Melting temperatureISO 3146225
Linear coefficient of thermal expansionTD:-40to23°CISO 11359-29E-05cm/cm/°C
Linear coefficient of thermal expansionTD:55to160°CISO 11359-21.5E-04cm/cm/°C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B221°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A207°C
Vicat softening temperatureISO 306/B50215°C
Melting temperatureISO 11357-3225°C
Linear coefficient of thermal expansionMD:--ISO 11359-22E-05cm/cm/°C
Linear coefficient of thermal expansionMD:-40to23°CISO 11359-22.5E-05cm/cm/°C
Linear coefficient of thermal expansionMD:55to160°CISO 11359-21.5E-05cm/cm/°C
Linear coefficient of thermal expansionTD:--ISO 11359-21.5E-04cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityISO 11831.5
MediumDensity1.29g/cm³
densityISO 11831.50g/cm³
Shrinkage rateTDISO 294-41.0%
Shrinkage rateMDISO 294-40.30%
Water absorption rateSaturation,23°C,2.00mmISO 620.35%
Water absorption rateEquilibrium,23°C,2.00mm,50%RHISO 620.15%
StickinessISO 30795.0cm³/g
FlowLength22.00mm,FlowLength350mm
Top out temperature170°C
SpecificHeatCapacity of Melt1730J/kg/°C
ThermalConductivityofMelt0.28W/m/K
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Dissipation factor100HzIEC 602502.5E-03
Dissipation factor1MHzIEC 602500.020
Compared to the anti leakage trace indexIEC 60112PLC 1
Surface resistivityIEC 600931E+13ohms
Volume resistivityIEC 60093>1.0E+15ohms·cm
Dielectric strength--IEC 60243-144KV/mm
Dielectric strength1.00mm5IEC 60243-131KV/mm
Relative permittivity100HzIEC 602504.40
Relative permittivity1MHzIEC 602504.10
Dissipation factor100HzASTM D1502.5E-03
Dissipation factor1kHzASTM D1507E-03
Dissipation factor1MHzASTM D1500.020
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.