PET AV2 370 /B DSM Additive Manufacturing
Properties:
Filler glass fiber reinforced material 35% filler by weight
Typical Applications:
Applications valves and valve components in the automotive industry
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Applications | valves | and valve components in the automotive industry |
| Properties: | Filler | glass fiber reinforced material | 35% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 9.5 | kJ/m² |
| -30°C | ISO 179/1eA | 9.5 | kJ/m² | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 69.3 | kJ/m² |
| -30°C | ISO 179/1eU | 50.4 | kJ/m² | |
| tensile strength | 23°C | ISO 527-2 | 185 | MPa |
| Elongation at Break | 23°C | ISO 527-2 | 2.5 | % |
| Tensile modulus | 23°C | ISO 527-2 | 12620 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPaUnannealed | ISO 75-2/Bf | 250 | °C |
| 1.80MPaAnnealed | ISO 75-2/Af | 235 | °C | |
| Vicat softening temperature | Melting Temperature | ISO 11357-3 | 255 | °C |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 1.4E-05 | cm/cm/°C |
| TD | ISO 11359-2 | 2.2E-05 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.63 | g/cm³ | |
| Water absorption rate | (23°C,24hr) | ISO 62 | 0.45 | % |
| (23°C,50RH) | ISO 62 | 0.18 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | >1.0E+15 | Ω.cm | |
| Dissipation factor | IEC 60250 | 0.013 | ||
| 相对漏电起痕指数 | IEC 60112 | 250 | V | |
| Dielectric strength | IEC 60243-1 | 0.840 | KV/mm | |
| Dielectric constant | IEC 60250 | 3.50 | 1MHz | |
| 100Hz | IEC 60250 | 3.70 | ||
| Dissipation factor | IEC 60250 | 3E-03 | ||
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | HB | 0.75mm | |
| UL -94 | HB | 1.50mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.