Share
Add to compare

PET AV2 370 /B DSM Additive Manufacturing

Properties:
Filler glass fiber reinforced material 35% filler by weight
Typical Applications:
Applications valves and valve components in the automotive industry
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Applications | valves | and valve components in the automotive industry
Properties:Filler | glass fiber reinforced material | 35% | filler by weight

Certificates

No Data...

Technical Data Sheet

mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact Strength23°CISO 179/1eA9.5kJ/m²
Charpy Notched Impact Strength-30°CISO 179/1eA9.5kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU69.3kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU50.4kJ/m²
tensile strength23°CISO 527-2185MPa
Elongation at Break23°CISO 527-22.5%
Tensile modulus23°CISO 527-212620MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature0.45MPaUnannealedISO 75-2/Bf250°C
Hot deformation temperature1.80MPaAnnealedISO 75-2/Af235°C
Vicat softening temperatureMelting TemperatureISO 11357-3255°C
Linear coefficient of thermal expansionMDISO 11359-21.4E-05cm/cm/°C
Linear coefficient of thermal expansionTDISO 11359-22.2E-05cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityISO 11831.63g/cm³
Water absorption rate(23°C,24hr)ISO 620.45%
Water absorption rate(23°C,50RH)ISO 620.18%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Volume resistivityIEC 60093>1.0E+15Ω.cm
Dissipation factorIEC 602500.013
Dissipation factor相对漏电起痕指数IEC 60112250V
Dielectric strengthIEC 60243-10.840KV/mm
Dielectric constantIEC 602503.501MHz
Dielectric constant100HzIEC 602503.70
Dissipation factorIEC 602503E-03
flame retardant performanceTest ConditionTest MethodTest ResultTest Unit
UL flame retardant ratingUL -94HB0.75mm
UL flame retardant ratingUL -94HB1.50mm
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.