PA6 WELLAMID Nylon 6000 GV 35 HWCP CP-Polymer-Technik GmbH & Co. KG
Properties:
Filler glass fiber reinforced material 35% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 35% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| tensile strength | 5mm/min,Break,23°C | ISO 527-2 | 190 | MPa |
| Elongation at Break | 5mm/min,Break,23°C | ISO 527-2 | 3.0 | % |
| Tensile modulus | 23°C | ISO 527-2 | 10500 | MPa |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 20.0 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 92.0 | kJ/m² |
| 弯曲模量 | DIN 52457 | 8800 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | 熔点 | Kofler | 215 | °C |
| 50N | ISO 306/A50 | 200 | °C | |
| 热变形温度 | ISO 179 | 220 | °C | |
| 热变形温度 | ISO 179 | 215 | °C | |
| 线膨胀系数 | DIN 53752 | 2E-05 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.41 | g/cm³ | |
| Water absorption rate | DIN 53495 | 1.8-2.3 | % | |
| Shrinkage rate | 0.20 | % | ||
| 0.80 | % | |||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | IEC 60250 | 0.020 | ||
| 相对漏电起痕指数 | IEC 60112 | 550 | V | |
| 表面电阻 | ISO 3915 | 1E+12 | ohm | |
| Volume resistivity | IEC 60093 | 1E+15 | Ω.cm | |
| Dielectric strength | IEC 60243-1 | 40.0 | KV/mm | |
| Dielectric constant | IEC 60250 | 4.0 | 1MHz | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | HB | 1.60mm | |
| UL -94 | HB | 3.20mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.