HIPS Bycolene® 576H BASF KOREA
24
- Properties:High rigidityheat-resistingHigh impact resistanceHigh gloss
- Usages:Household appliances
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| gloss | 60° | ASTM D523 | 70 |
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179 | 120 kJ/m² |
| -30°C | ISO 179 | 70 kJ/m² |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| bending strength | ISO 178 | 44.0 Mpa | |
| Bending modulus | ISO 178 | 2100 Mpa | |
| Tensile strain | Break,23°C | ISO 527-2 | 30 % |
| Yield,23°C | ISO 527-2 | 1.6 % | |
| tensile strength | Yield,23°C | ISO 527-2 | 30.0 Mpa |
| Tensile modulus | ISO 527-2 | 2050 Mpa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Vicat softening temperature | -- | ISO 306/B50 | 90.0 °C |
| -- | ISO 306/A50 | 98.0 °C | |
| Hot deformation temperature | 1.8MPa,Annealed | ISO 75-2/A | 78.0 °C |
| 0.45MPa,Annealed | ISO 75-2/B | 88.0 °C | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 1E-04 cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | <0.10 % |
| Saturation,23°C | ISO 62 | <0.10 % | |
| Shrinkage rate | ISO 294-4 | 0.40-0.70 % | |
| Melt Volume Flow Rate (MVR) | 200°C/5.0kg | ISO 1133 | 5.50 cm3/10min |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Dissipation factor | 1MHz | IEC 60250 | 4E-04 |
| Dielectric constant | 1MHz | IEC 60250 | 2.50 |
| 100Hz | IEC 60250 | 2.50 | |
| Dielectric strength | 1.50mm | IEC 60243-1 | 160 KV/mm |
| Volume resistivity | IEC 60093 | >1.0E+18 ohms·cm | |
| Surface resistivity | IEC 60093 | >1.0E+13 ohms |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Ball Pressure Test | ISO 2039-1 | 83.0 Mpa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.