Share
Add to compare

PPS 1140L4 SF3001 CELANESE USA

69

Form:Granules | Grade:Flame retardant grade

Properties:
Flame retardantHigh temperature resistanenhanceGlass fiber reinforcedInjection gradeMedium melt viscosity
Typical Applications:
Fiber gradeDuring injection moldingSlight flash
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Fiber grade | During injection molding | Slight flash
Properties:Flame retardant | High temperature resistan | enhance | Glass fiber reinforced | Injection grade | Medium melt viscosity

Certificates

No Data...

Technical Data Sheet

Filling analysisTest ConditionTest MethodTest ResultTest Unit
SpecificHeatCapacity of MeltInternal Method1500J/kg/°C
impact performanceTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact Strength-30°CISO 179/1eA10kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA10kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU53kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU53kJ/m²
Impact strength of cantilever beam gap-30°CISO 180/1A10kJ/m²
Impact strength of cantilever beam gap23°CISO 180/1A10kJ/m²
Suspended wall beam without notch impact strength23°CISO 180/1U34kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.38mmUL 94V-0
UL flame retardant rating1.5mmUL 94V-0
UL flame retardant rating3.0mmUL 945VA
Extreme Oxygen IndexISO 4589-247%
Basic PerformanceTest ConditionTest MethodTest ResultTest Unit
densityISO 11831.65g/cm³
Water absorption rateASTM-D5700.02%
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
tensile strengthISO 527195Mpa
Tensile modulusISO 52714700Mpa
bending strengthISO 178285Mpa
Bending modulusISO 17814500Mpa
Impact strength of cantilever beam gapISO 180/1A10kJ/m²
Rockwell hardnessASTM-D785100R-Scale
tensile strengthBreak,23°CASTM D638200Mpa
tensile strengthBreakISO 527-2/1A/5195Mpa
elongationBreak,23°CASTM D6381.7%
elongationBreakISO 527-2/1A/51.9%
Bending modulus23°CISO 17814500Mpa
bending strengthISO 178285Mpa
Tensile modulus-40°CASTM D63814500Mpa
Tensile modulus75°CASTM D63811900Mpa
Tensile modulus150°CASTM D6384270Mpa
Tensile modulus200°CASTM D6383240Mpa
Tensile modulus--ISO 527-2/1A/114700Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.80MpaISO 75-A270°C
UL flame retardant ratingUL 94V-0
Linear coefficient of thermal expansionTDISO 11359-24.2E-05cm/cm/°C
Hot deformation temperature0.45MPa,AnnealedASTM D648280°C
Hot deformation temperature1.8MPa,UnannealedASTM D648265°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A270°C
Hot deformation temperature8.0MPa,UnannealedISO 75-2/C215°C
Glass transition temperatureISO 11357-290.0°C
Melting temperatureISO 11357-3280°C
Linear coefficient of thermal expansionMDISO 11359-22.6E-05cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateISO 294-40.2-0.6%
Shrinkage rateTDISO 294-40.40-0.60%
Shrinkage rateMDISO 294-40.20-0.60%
Water absorption rateSaturation,23°CISO 620.020%
densityASTMD7921.65g/cm³
Specific volumeASTM D7920.611cm³/g
Shrinkage rateMDASTM D9550.20-0.30%
Shrinkage rateTDASTM D9550.50-0.70%
Biochemical propertiesTest ConditionTest MethodTest ResultTest Unit
Filling amount40%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityIEC 60093>1.0E+15ohms
Volume resistivity--ASTM D2571E+16ohms·cm
Volume resistivity--IEC 60093>1.0E+15ohms·cm
Dielectric strengthIEC 60243-128KV/mm
Dielectric constant1kHzASTM D1503.50
Dielectric constant1MHzASTM D1503.50
Dielectric constant1MHzIEC 602504.60
Dissipation factor1kHzASTM D1501E-03
Dissipation factor1MHzASTM D1501E-03
Dissipation factor1MHzIEC 602506.2E-03
Arc resistanceASTM D495134sec
Compared to the anti leakage trace indexIEC 60112PLC 4
hardnessTest ConditionTest MethodTest ResultTest Unit
Rockwell hardnessM-ScaleASTM D785100
Rockwell hardnessM-SaleISO 2039-2100
Supplementary InformationTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateInternal Method3.18mm
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.