PBT DR51-1001 SABIC INNOVATIVE US
98
Form:Granules | Grade:Injection grade
Properties:
Glass fiber reinforcedElectrical performance
Typical Applications:
Non specific foodLawn equipmentGarden equipmentIndustrial applicationsAutomotive External PartsElectrical fieldElectronic fieldArchitectural application fieldOutdoor applicationsElectrical appliancesEngine hood partsMedical suppliesNursing suppliesPlastic bagAutomotive interior partsCastersAerospace Applications
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Non specific food | Lawn equipment | Garden equipment | Industrial applications | Automotive External Parts | Electrical field | Electronic field | Architectural application field | Outdoor applications | Electrical appliances | Engine hood parts | Medical supplies | Nursing supplies | Plastic bag | Automotive interior parts | Casters | Aerospace Applications |
| Properties: | Glass fiber reinforced | Electrical performance |
Certificates

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Suspended wall beam without notch impact strength | /,23℃ | ASTM D4812 | 534 | J/m |
| Impact strength of cantilever beam gap | 23℃ | ASTM D256 | 53 | J/m |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | 1.3 mm | ASTM D790 | 4820 | Mpa |
| bending strength | 1.3 mm,Break | ASTM D790 | 144 | Mpa |
| Elongation at Break | Type I, 5 | ASTM D638 | 5 | % |
| tensile strength | Type I, 5,Break | ASTM D638 | 93 | Mpa |
| thermal properties | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | -40°C to,Flow | ASTM E831 | 21.6 | E-6/°C |
| 60°C to,Flow | ASTM E831 | 21.6 | E-6/°C | |
| combustion performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 10°C/min,HB | UL 94 | 0.71 | mm |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bi Rong | ASTM D792 | 0.71 | cm³/g | |
| Water absorption rate | 24 hours | ASTM D570 | 0.07 | |
| Shrinkage rate | flow, 3.2 | Internal | 0.6-0.9 | |
| flow, 1.5 | Internal | 0.4-0.6 | ||
| xflow, 3.2,Across Flow | Internal | 0.8-1.1 | ||
| xflow, 1.5Across Flow | Internal | 0.5-0.8 | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Hardness (Rockwell R) | ASTM D785 | 118 | R |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.