PEEK VAMPLUB K 00U 1 TF VAMP TECH ITALY
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ISO 180/A | 9.0 | kJ/m² | |
| Suspended wall beam without notch impact strength | ISO 180 | 无断裂 | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 3.2mm | UL 94 | V-0 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| elongation | Break | ASTM D638 | >50 | % |
| Friction coefficient | Dynamic | ASTM D1894 | 0.39 | |
| Static | ASTM D1894 | 0.35 | ||
| 磨损因数2 | ASTM D1894 | 21.0 | 10^-10m³h/N·m·h | |
| Tensile modulus | ASTM D638 | 3100 | MPa | |
| tensile strength | Yield | ASTM D638 | 80.0 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ASTM D15253 | >300 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.31 | g/cm³ | |
| Shrinkage rate | MD | ASTM D955 | 0.70 | % |
| TD | ASTM D955 | 1.2 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.