PA6T ARLEN™  E440NK MITSUI CHEM JAPAN

196
  • Properties:
    Glass fiber reinforced
    Flame retardant
  • Usages:
    Electrical applications
    Electronic and electrical components

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
Shrinkage rateASTM D9550.20 %
Shrinkage rateASTM D9550.60 %
Water absorption rateASTM D5701.4 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessASTM D785100
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94V-0
Mechanical propertiesTest ConditionTest MethodTest Result
tensile strength ASTM D638190 Mpa
elongationASTM D6383.0 %
Flexural modulusASTM D79017000 Mpa
bending strengthASTM D790280 Mpa
Electrical performanceTest ConditionTest MethodTest Result
Volume resistivityASTM D2571.0E+15 ohms·cm
dielectric strengthASTM D14918 KV/mm
dielectric constantASTM D1504.10
Dissipation FactorASTM D1500.011
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureASTM D648300 °C
Glass Transition Temperature95.0 °C
melting temperature320 °C
Linear coefficient of thermal expansionASTM E8311.8E-5 cm/cm/°C
Linear coefficient of thermal expansionASTM E8316.9E-5 cm/cm/°C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.