Phenolic Plenco 03303 (Injection) Plastics Engineering Co.
0
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Charpy Notched Impact Strength | ASTM D256 | 18.0 J/m | |
| Impact strength of cantilever beam gap | ASTM D256 | 19 J/m |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 1.5mm | UL 94 | V-0 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| compressive strength | ASTM D695 | 180 MPa | |
| bending strength | ASTM D790 | 82.9 MPa | |
| Bending modulus | ASTM D790 | 8630 MPa | |
| elongation | Break | ASTM D638 | 0.80 % |
| tensile strength | ASTM D638 | 57.0 MPa | |
| Tensile modulus | ASTM D638 | 10000 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Continuous use temperature | ASTM D794 | 200 °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 168 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | 24hr | ASTM D570 | 0.33 % |
| Shrinkage rate | MD | ASTM D955 | 0.84 % |
| Apparent density | ASTM D1895 | 0.62 g/cm³ | |
| density | ASTM D792 | 1.54 g/cm³ |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 3 |
| Arc resistance | ASTM D495 | 180 sec | |
| Dissipation factor | 1MHz | ASTM D150 | 0.070 |
| Dielectric constant | 1MHz | ASTM D150 | 5.60 |
| Dielectric strength | --4 | ASTM D149 | 6.0 kV/mm |
| --3 | ASTM D149 | 9.2 kV/mm | |
| Volume resistivity | ASTM D257 | 3.1E+11 ohms·cm |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Rockwell hardness | E-Sale | ASTM D785 | 82 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.