plas
Log In

Phenolic Plenco 03303 (Injection) Plastics Engineering Co.

0

Technical Data Sheet

impact performanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthASTM D25618.0 J/m
Impact strength of cantilever beam gapASTM D25619 J/m
flammabilityTest ConditionTest MethodTest Result
UL flame retardant rating1.5mmUL 94V-0
mechanical propertiesTest ConditionTest MethodTest Result
compressive strengthASTM D695180 MPa
bending strengthASTM D79082.9 MPa
Bending modulusASTM D7908630 MPa
elongationBreakASTM D6380.80 %
tensile strengthASTM D63857.0 MPa
Tensile modulusASTM D63810000 MPa
thermal performanceTest ConditionTest MethodTest Result
Continuous use temperatureASTM D794200 °C
Hot deformation temperature1.8MPa,UnannealedASTM D648168 °C
Physical propertiesTest ConditionTest MethodTest Result
Water absorption rate24hrASTM D5700.33 %
Shrinkage rateMDASTM D9550.84 %
Apparent densityASTM D18950.62 g/cm³
densityASTM D7921.54 g/cm³
Electrical performanceTest ConditionTest MethodTest Result
Compared to the anti leakage trace indexCTIUL 746PLC 3
Arc resistanceASTM D495180 sec
Dissipation factor1MHzASTM D1500.070
Dielectric constant1MHzASTM D1505.60
Dielectric strength--4ASTM D1496.0 kV/mm
Dielectric strength--3ASTM D1499.2 kV/mm
Volume resistivityASTM D2573.1E+11 ohms·cm
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessE-SaleASTM D78582
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.