PA6 Ultraflow K-FG3 DSM Additive Manufacturing

Properties:
Filler glass fiber reinforced material 15% filler by weight
Product Description
Certificates(0)
Datasheet

Product Description

Properties:Filler | glass fiber reinforced material | 15% | filler by weight

Certificates

No Data...

Technical Data Sheet

mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
tensile strength23°CISO 527-2110MPa
Elongation at Break23°CISO 527-23.00%
bending strength23°CISO 178160MPa
Bending modulus23°CISO 1784500MPa
Charpy Notched Impact Strength23°CISO 179/1eA6.00kJ/m²
Charpy Notched Impact Strength-30°CISO 179/1eA5.00kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU25kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU20kJ/m²
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Linear coefficient of thermal expansionTDISO 11359-28E-05cm/cm/°C
Hot deformation temperature0.45MPaUnannealedISO 75-2/Bf215°C
Hot deformation temperature1.80MPaAnnealedISO 75-2/Af195°C
Vicat softening temperatureMelting TemperatureISO 11357-3220°C
Linear coefficient of thermal expansionMDISO 11359-23E-05cm/cm/°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateMDISO 294-40.31%
Shrinkage rateTDISO 294-40.93%
Water absorption rate(23°C,24hr)ISO 627.60%
Water absorption rate(23°C,50RH)ISO 622.30%
densityISO 11831.23g/cm³
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Volume resistivityIEC 60093>1.0E+15Ω.cm
Dielectric constant23°CIEC 602503.50100Hz
Dielectric constant23°CIEC 602504.701MHz
Dissipation factor23°CIEC 602505.5E-03100Hz
Dissipation factor23°CIEC 602500.0181MHz
flame retardant performanceTest ConditionTest MethodTest ResultTest Unit
UL flame retardant ratingUL -94HB1.60mm
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.