Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ISO 62 | 0.10 % |
density | | ISO1183 | 1.65 g/cm³ |
Water absorption rate | | ISO62 | 0.10 % |
density | | ISO 1183 | 1.65 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | HB |
Hot filament ignition temperature | | IEC60695-2-13 | 650 °C |
Heat distortion temperature | Test Condition | Test Method | Test Result |
---|
flammability | | UL 94 | HB |
flammability | | IEC 60695-2-13 | 650 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2/5 | 11000 MPa |
Tensile stress | | ISO 527-2/5 | 150 MPa |
Tensile strain | | ISO 527-2/5 | 1.5 % |
Impact strength of cantilever beam gap | | ISO 180/1A | 7.0 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180/1A | 9.0 kJ/m² |
Tensile modulus | | ISO527-2/5 | 11000 MPa |
Tensile stress | | ISO527-2/5 | 150 MPa |
Tensile strain | | ISO527-2/5 | 1.5 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ISO180/1A | 7.0 kJ/m² |
Impact strength of cantilever beam gap | | ISO180/1A | 9.0 kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO 75-2/A | 215 °C |
| | ISO 306/B | 215 °C |
| Melting Temperature | ISO 11357 | 225 °C |
| | ISO75-2/B | 215 °C |
vicat | | ISO306/B | 215 °C |
melting temperature | | ISO11357 | 225 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.