PP Homopolymer E-RIALFILL H 15 S 20 T3 RIALTI ITALY
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 34 | kJ/m² |
| Impact strength of cantilever beam gap | -20°C | ISO 180/1A | 2.0 | kJ/m² |
| 23°C | ISO 180/1A | 2.5 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.5mm | UL 94 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | 23°C | ISO 178 | 2400 | MPa |
| bending strength | 23°C | ISO 178 | 45.0 | MPa |
| tensile strength | Yield,23°C | ISO 527-2/20 | 30.0 | MPa |
| Break,23°C | ISO 527-2/20 | 22.0 | MPa | |
| Tensile strain | Yield,23°C | ISO 527-2/20 | 5.0 | % |
| Break,23°C | ISO 527-2/20 | 30 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | 125°C | IEC 335 | 通过 | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 8E-05 | cm/cm/°C |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 110 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 63.0 | °C | |
| Vicat softening temperature | -- | ISO 306/A50 | 152 | °C |
| -- | ISO 306/B50 | 94.0 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 230°C/2.16kg | ISO 1133 | 15 | g/10min |
| Shrinkage rate | TD | ISO 294-4 | 1.2 | % |
| MD | ISO 294-4 | 1.2 | % | |
| Water absorption rate | 23°C,24hr | ISO 62 | 0.020 | % |
| ash content | ISO 3451 | 20 | % | |
| density | ISO 1183 | 1.05 | g/cm³ | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | ShoreD,15Sec | ISO 868 | 75 | |
| aging | Test Condition | Test Method | Test Result | Test Unit |
| Accelerated oven aging | 150°C | ISO 4577 | 4.2 | day |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.