PA66 Staramide AG6ST43H EUROSTAR FRANCE
Properties:
Filler glass fiber reinforced material
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 悬壁梁Notched冲击强度 | ISO 180/1A | 18.0 | kJ/m² |
| -40°C | ISO 180/1A | 16.0 | kJ/m² | |
| 23°C | ISO 180/1A | 22.0 | kJ/m² | |
| Tensile modulus | 1mm/min,23°C | ISO 527-2 | 5800 | MPa |
| Elongation at Break | 5mm/min,23°C | ISO 527-2 | 5.0 | % |
| tensile strength | 5mm/min,23°C | ISO 527-2 | 110 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | 维卡软化温度 | ISO 306/B120 | 250 | °C |
| MD | ISO 11359-2 | 4E-04 | cm/cm/°C | |
| Hot deformation temperature | 1.80MPaAnnealed | ISO 75-2/Af | 225 | °C |
| 0.45MPaUnannealed | ISO 75-2/Bf | 250 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD | ISO 294-4 | 0.30-0.50 | % |
| density | ISO 1183 | 1.32 | g/cm³ | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | HB | 1.60mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.