PA66 A3 GF35 V0 NC CELANESE USA
145
Form:Granules | Grade:Flame retardant reinforcement
Properties:
enhanceConductive
Typical Applications:
Automotive sectorElectronic and Electrical ApplicationsHome Furnishings
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive sector | Electronic and Electrical Applications | Home Furnishings |
| Properties: | enhance | Conductive |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 45 | kJ/m² |
| -30°C | ISO 179/1eU | 48 | kJ/m² | |
| tensile strength | 23°C | ISO 527-2 | 150 | Mpa |
| Elongation at Break | 23°C | ISO 527-2 | 2.5 | % |
| Tensile modulus | 23°C | ISO 527-2 | 11500 | Mpa |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 8.0 | kJ/m² |
| -30°C | ISO 179/1eA | 7.0 | kJ/m² | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPaUnannealed | ISO 75-2/Bf | 220 | °C |
| 1.80MPaAnnealed | ISO 75-2/Af | 210 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD | ISO 294-4 | 0.30 | % |
| TD | ISO 294-4 | 1.00 | % | |
| Water absorption rate | (23°C,24hr) | ISO 62 | 1.40 | % |
| (23°C,50RH) | ISO 62 | 4.00 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | 1E+15 | Ω.cm | |
| Surface resistivity | IEC 60093 | 1E+13 | Ω.cm | |
| Dielectric strength | 2.00mm | IEC 60243-1 | 18 | KV/mm |
| Dissipation factor | 相对漏电起痕指数 | IEC 60112 | 600 | V |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | V-0 | 0.75mm | |
| UL -94 | V-0 | 1.50mm | ||
| UL -94 | V-0 | 3.00mm | ||
| Extreme Oxygen Index | ISO 4589-2 | 31 | % | |
| Ignition temperature of heating wire | 0.75mm | IEC 60695-2-12 | 800 | °C |
| 1.50mm | IEC 60695-2-12 | 825 | °C | |
| 3.00mm | IEC 60695-2-12 | 850 | °C | |
| Relative temperature of heating wire | 0.75mm | IEC 60695-2-13 | 960 | °C |
| 1.50mm | IEC 60695-2-13 | 960 | °C | |
| 3.00mm | IEC 60695-2-13 | 960 | °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.