Technical Data Sheet
| processability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Spiral flow length | -- | CM | ||
| Shrinkage rate | ISO 294-4 | 0.4-0.8 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | ISO 527 | 120 | Mpa | |
| Charpy Notched Impact Strength | Notched | ISO 179(leA) | 14 | kJ/m² |
| Bending modulus | ISO 178 | 7.8*103 | Mpa | |
| bending strength | ISO 178 | 190 | Mpa | |
| elongation | Break | ISO 527 | 4.2 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.82MPa | ISO 75f | 202 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23℃,24hr | ISO 62 | 0.09 | % |
| density | ISO 1183 | -- | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| ash content | 30 | % | ||
| Compared to the anti leakage trace index | IEC 60112 | PLC 2 | ||
| Arc resistance | IEC 61621 | -- | sec | |
| Dielectric strength | IEC 60243 | 32 | KV/m | |
| Volume resistivity | IEC 60093 | 1*1014 | Ω。m | |
| Dielectric loss | 106HZ,Tangent | IEC 60250 | 1.7*10-2 | |
| Dielectric constant | 106HZ | IEC 60250 | 3.4 | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | V-0(0.8mm) |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.