| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | -- | ASTM D256 | 3.4 | kN/m |
| -- | JISK7111 | 3.4 | kN/m | |
| Impact strength of cantilever beam gap | -- | ASTM D256 | 2.9 | kN/m |
| -- | JISK6911 | 2.9 | kN/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.60mm | UL 94 | V-0 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | JISK6911 | 56.0 | MPa | |
| bending strength | ASTM D790 | 95.0 | MPa | |
| JISK7203 | 95.0 | MPa | ||
| tensile strength | ASTM D638 | 56.0 | MPa | |
| compressive strength | ASTM D695 | 210 | MPa | |
| Compressive stress | JISK6911 | 210 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | JISK7207 | 190 | °C |
| RTI Elec | UL 746 | 150 | °C | |
| RTI Imp | UL 746 | 150 | °C | |
| RTI Str | UL 746 | 150 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 190 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | -- | JISK6915 | 9.5 | % |
| -- | ASTM D955 | 9.5 | % | |
| Water absorption rate | 24hr | ASTM D570 | 0.16 | % |
| 23°C,24hr | JISK6911 | 0.16 | % | |
| density | ASTM D792 | 1.56 | g/cm³ | |
| JISK7112 | 1.56 | g/cm³ | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | -- | ASTM D149 | 13 | kV/mm |
| -- | JISK6915 | 13 | kV/mm | |
| Arc resistance | ASTM D495 | PLC 4 | ||
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 4 | |
| insulation resistance | --2 | ASTM D257 | 1E+10 | ohms |
| --2 | JISK6915 | 1E+10 | ohms | |
| --3 | JISK6915 | 1E+08 | ohms | |
| Volume resistivity | ASTM D257 | 1E+12 | ohms·cm | |
| JISK6911 | 1E+12 | ohms·cm | ||
| insulation resistance | --3 | ASTM D257 | 1E+08 | ohms |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| shelf-life | 12 | month |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.