Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.37 g/cm³ |
Shrinkage rate | | ASTM D955 | 0.60 % |
Water absorption rate | | ASTM D570 | 0.20 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | R-Scale | ASTM D785 | 120 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Suspended wall beam without notch impact strength | | ASTM D4812 | 800 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 85 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTM D638 | 3100 MPa |
tensile strength | | ASTM D638 | 82.7 MPa |
elongation | Break | ASTM D638 | 10 % |
Flexural modulus | | ASTM D790 | 2760 MPa |
bending strength | | ASTM D790 | 110 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | ASTM D257 | 1E+16 ohms·cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 207 °C |
Heat distortion temperature | | ASTM D648 | 204 °C |
Linear coefficient of thermal expansion | | ASTM D696 | 5.6E-05 cm/cm/°C |
thermal conductivity | | ASTMC177 | 0.27 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.