PA66 A30H1V30 V0 SOLVAY SHANGHAI
163
Form:Granules | Grade:Injection grade
Properties:
Glass fiber reinforced 30thermal stabilityFlame retardant V0
Typical Applications:
Electronic and Electrical Applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electronic and Electrical Applications |
| Properties: | Glass fiber reinforced 30 | thermal stability | Flame retardant V0 |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ISO 180/1A | 9.80 | kJ/m² | |
| Impact strength of simply supported beam without notch | ISO 179/1eU | 45 | kJ/m² | |
| Charpy Notched Impact Strength | ISO 179/1eA | 9 | kJ/m² | |
| tensile strength | Break | ISO 527 type 1 A | 95 | Mpa |
| Elongation at Break | ISO 527 type 1 A | 2.5 | % | |
| Tensile modulus | ISO 527 type 1 A | 8800 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8mpa | ISO 75/Af | 220 | °C |
| Melting temperature | ISO 11357 | 263 | °C | |
| Hot wire | IEC 60695-2-13 | 775 | °C | |
| IEC 60695-2-12 | 960 | °C | ||
| UL flame retardant rating | 3.2mm | ISO 1210/UL 94 | V-0 | |
| 1.6mm | ISO 1210/UL 94 | V-0 | ||
| 0.8mm | ISO 1210/UL 94 | V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.