PA66 A30H1V30 V0
68
- Properties:Glass fiber reinforced 30thermal stabilityFlame retardant V0
- Usages:Electronic and Electrical Applications
Technical Data Sheet
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527 type 1 A | 8800 Mpa | |
elongation at break | ISO 527 type 1 A | 2.5 % | |
tensile strength | ISO 527 type 1 A | 95 Mpa | |
Charpy Notched Impact Strength | ISO 179/1eA | 9 kJ/m² | |
Impact strength of simply supported beam without notch | ISO 179/1eU | 45 kJ/m² | |
Impact strength of cantilever beam gap | ISO 180/1A | 9.80 kJ/m² |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | ISO 1210/UL 94 | V-0 | |
ISO 1210/UL 94 | V-0 | ||
ISO 1210/UL 94 | V-0 | ||
Glow wire | IEC 60695-2-12 | 960 °C | |
IEC 60695-2-13 | 775 °C | ||
melting temperature | ISO 11357 | 263 °C | |
Heat distortion temperature | ISO 75/Af | 220 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.