POM N2200G43 BASF GERMANY
189
Form:Granules | Grade:Injection grade
Properties:
Glass fiber reinforcedHigh rigidityhigh strengthFiller: Glass fiber reinf20%Filler by weight
Typical Applications:
Fiber gradeElectrical fieldElectronic fieldHousehold appliancesHousehold appliancesLighting fixturesAutomotive sector
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Fiber grade | Electrical field | Electronic field | Household appliances | Household appliances | Lighting fixtures | Automotive sector |
| Properties: | Glass fiber reinforced | High rigidity | high strength | Filler: Glass fiber reinf | 20% | Filler by weight |
Certificates

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 50 | kJ/m² |
| -30°C | ISO 179/1eU | 50 | kJ/m² | |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 7.5 | kJ/m² |
| -30°C | ISO 179/1eA | 7.5 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile creep modulus | 1000hr | ISO 899-1 | 4500 | Mpa |
| Tensile strain | Break | ISO 527-2 | 3.0 | % |
| tensile strength | Break | ISO 527-2 | 115 | Mpa |
| Tensile modulus | ISO 527-2 | 7200 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 161 | °C |
| Melting temperature | ISO 11357-3 | 168 | °C | |
| Linear coefficient of thermal expansion | MD:23to55°C | ISO 11359-2 | 5E-05 | cm/cm/°C |
| Maximum operating temperature | 短周期操作 | 110 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.15 | % |
| Saturation,23°C | ISO 62 | 0.90 | % | |
| Shrinkage rate | MD | ISO 294-4 | 1.0 | % |
| TD | ISO 294-4 | 1.3 | % | |
| Melt Volume Flow Rate (MVR) | 190°C/2.16kg | ISO 1133 | 4.00 | cm3/10min |
| Apparent density | 0.85 | g/cm³ | ||
| density | ISO 1183 | 1.54 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | SolutionA | IEC 60112 | PLC 0 | |
| Dissipation factor | 1MHz | IEC 60250 | 7E-03 | |
| Relative permittivity | 1MHz | IEC 60250 | 4.10 | |
| Dielectric strength | IEC 60243-1 | 85 | KV/mm | |
| Volume resistivity | IEC 60093 | 1E+14 | ohms·cm | |
| Surface resistivity | IEC 60093 | 1E+14 | ohms | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | H358/30 | ISO 2039-1 | 164 | Mpa |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| ISOType | ISO 9988-1 | POM-K.M-GNR.02-003.GF20 | ||
| Automotive Materials | >1.00mm | FMVSS302 | Passed |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.