PP AMTOPP VS18 Inteplast Group
Typical Applications:
film
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | film |
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| gloss | 45° | ASTM D2457 | 90 | |
| turbidity | ASTM D1003 | 2.0 | % | |
| gloss | 45° | ASTM D2457 | 90 | |
| turbidity | ASTM D1003 | 2.0 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Friction coefficient | Static | ASTM D1894 | 0.25 | |
| Dynamic | ASTM D1894 | 0.20 | ||
| Static | ASTM D1894 | 0.25 | ||
| Dynamic | ASTM D1894 | 0.20 | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| dimensional stability | AcrossFlow,130°C | <3.0 | % | |
| Flow,130°C | <5.0 | % | ||
| AcrossFlow,130°C | <3.0 | % | ||
| Flow,130°C | <5.0 | % | ||
| film | Test Condition | Test Method | Test Result | Test Unit |
| film thickness | 18 | µm | ||
| tensile strength | MD:Yield | ASTM D882 | 138 | MPa |
| TD:Yield | ASTM D882 | 221 | MPa | |
| elongation | MD:Break | ASTM D882 | 140 | % |
| TD:Break | ASTM D882 | 60 | % | |
| Water vapor permeability | 38°C,90%RH | ASTMF1249 | 7.0 | g/m²/24hr |
| consumption | 62.6 | m²/kg | ||
| film thickness | 18 | µm | ||
| tensile strength | MD:Yield | ASTM D882 | 138 | MPa |
| TD:Yield | ASTM D882 | 221 | MPa | |
| elongation | MD:Break | ASTM D882 | 140 | % |
| TD:Break | ASTM D882 | 60 | % | |
| Water vapor permeability | 38°C,90%RH | ASTMF1249 | 7.0 | g/m²/24hr |
| consumption | 62.6 | m²/kg | ||
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| SurfaceEnergy | --4 | ASTM D2578 | 40 | dyne/cm |
| --5 | ASTM D2578 | 36 | dyne/cm | |
| --4 | ASTM D2578 | 40 | dyne/cm | |
| --5 | ASTM D2578 | 36 | dyne/cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.