PBT+PET SCHULADUR® A1 GF 30 HF FR 1

0
  • Properties:
    Filler
    glass fiber reinforced material
    30%
    filler by weight

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO 1183/A1.68 g/cm³
Melt volume flow rateISO 113354.0 cm³/10min
flammabilityTest ConditionTest MethodTest Result
burning rateISO 37950.0 mm/min
Hot filament ignition temperatureIEC 60695-2-13675 °C
Hot filament ignition temperatureIEC 60695-2-13675 °C
Limiting Oxygen IndexISO 4589-234 %
burning rateISO 37950.0 mm/min
burning rateISO 37950.0 mm/min
UL flame retardant ratingUL 94V-0
UL flame retardant ratingUL 94V-0
UL flame retardant ratingUL 94V-0
UL flame retardant ratingIEC 60695-11-10,-20V-0
UL flame retardant ratingIEC 60695-11-10,-20V-0
UL flame retardant ratingIEC 60695-11-10,-20V-0
Burning wire flammability indexIEC 60695-2-12960 °C
Burning wire flammability indexIEC 60695-2-12960 °C
Burning wire flammability indexIEC 60695-2-12960 °C
Hot filament ignition temperatureIEC 60695-2-13675 °C
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO 179/1eA7.0 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU40 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eU46 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA7.0 kJ/m²
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO 527-2/1A/112000 MPa
tensile strength BreakISO 527-2/1A/5148 MPa
Tensile strainBreakISO 527-2/1A/52.0 %
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC 60093>1.0E+15 ohms
Volume resistivityIEC 60093>1.0E+13 ohms·cm
Compared to the Leakage Tracking Index (CTI)IEC 60112PLC 3
Thermal performanceTest ConditionTest MethodTest Result
Hot deformation temperature (HDT)ISO 75-2/Af198 °C
vicatISO 306/A50218 °C
vicatISO 306/B50190 °C
Hot deformation temperature (HDT)ISO 75-2/Bf219 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.