Share
Add to Compare

NBR NANCAR® 1043 Nantex Industry Co., Ltd.

Product Description
Certificates(0)
Datasheet

Product Description

Certificates

No Data...

Technical Data Sheet

elastomerTest ConditionTest MethodTest ResultTest Unit
tensile strength300%Strain7ASTM D41212.7MPa
tensile strengthYield2ASTM D41223.4MPa
tensile strengthYield3ASTM D41223.9MPa
tensile strength300%Strain5ASTM D41210.9MPa
Permanent compression deformation100°C,70hrASTM D39555%
tear strengthASTM D62450.0kN/m
elongationBreak7ASTM D412500%
elongationBreak6ASTM D412520%
elongationBreak5ASTM D412550%
tensile strengthYield4ASTM D41224.6MPa
tensile strength300%Strain6ASTM D41211.5MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Heat lossASTM D56880.40%
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Soluble inMEK100%
stabilizerSlightly-staining
bound acrylonitrile contentInternal Method33.0%
Mooney viscosityML1+4,100°CASTM D164683MU
density0.970g/cm³
hardnessTest ConditionTest MethodTest ResultTest Unit
Shore hardnessShoreA4ASTM D224069
Shore hardnessShoreA3ASTM D224068
Shore hardnessShoreA2ASTM D224067
agingTest ConditionTest MethodTest ResultTest Unit
Volume change100°C,70hr,ASTM标准油(1号)ASTM D4711.0%
Volume change100°C,70hr,ASTM标准油(3号)ASTM D47122%
Change rate of hardness (Shore) in the air支撐A,100°C,70hr,在ASTM#3油中ASTM D471-12
Change rate of hardness (Shore) in the air支撐A,100°C,70hr,在ASTM#1油中ASTM D4711.0
Change rate of ultimate elongation in air100°C,70hrASTM D865-25%
Change rate of tensile strength in air100°C,70hrASTM D865-4.0%
Change rate of ultimate elongation in air100°C,70hr,在ASTM#3油中ASTM D471-21%
Change rate of ultimate elongation in air100°C,70hr,在ASTM#1油中ASTM D471-22%
Change rate of tensile strength in air100°C,70hr,在ASTM#3油中ASTM D471-21%
Change rate of tensile strength in air100°C,70hr,在ASTM#1油中ASTM D471-5.0%
Change rate of hardness (Shore) in the airShoreA,100°C,70hrASTM D8655.0
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.