PA6 6 GF15 A SCHULMAN USA
71
Form:Granules | Grade:Thin film grade
Properties:
Filler: Glass fiber reinf15% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler: Glass fiber reinf | 15% filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 45 | kJ/m² |
| -30°C | ISO 179/1eU | 40 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Burning wire flammability index | 3.0mm | IEC 60695-2-12 | -- | °C |
| 1.5mm | IEC 60695-2-12 | -- | °C | |
| UL flame retardant rating | 3.0mm | IEC 60695-11-10,-20 | HB | |
| 1.5mm | IEC 60695-11-10,-20 | HB | ||
| 0.75mm | IEC 60695-11-10,-20 | HB | ||
| Burning rate | ISO 3795 | <100 | mm/min | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending strain | ISO 178 | 6.5 | % | |
| bending strength | ISO 178 | 170 | Mpa | |
| Bending modulus | ISO 178 | 4300 | Mpa | |
| Tensile strain | Break | ISO 527-2/1A/5 | 3.5 | % |
| tensile strength | Break | ISO 527-2/1A/5 | 120 | Mpa |
| Tensile modulus | ISO 527-2/1A/1 | 5800 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | -- | ISO 306/B50 | 210 | °C |
| -- | ISO 306/A50 | 215 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/Af | 200 | °C |
| 0.45MPa,Unannealed | ISO 75-2/Bf | 210 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Stickiness | ISO 307 | 145 | cm³/g | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | H358/30 | ISO 2039-1 | 174 | Mpa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.