PA66 S223-6G-FC DSM HOLAND
29
Form:Granules | Grade:Injection grade
Properties:
Glass fiber reinforcedHigh rigidity
Typical Applications:
Electrical applicationshousehold electrical appliances
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical applications | household electrical appliances |
| Properties: | Glass fiber reinforced | High rigidity |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | -30°C | ISO 179/1eA | 9.0 | kJ/m² |
| 23°C | ISO 179/1eA | 10 | kJ/m² | |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 65 | kJ/m² |
| 23°C | ISO 179/1eU | 81 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Flammability level | UL 94 | HB | ||
| UL 94 | HB | |||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2 | 9950 | Mpa | |
| tensile strength | Break | ISO 527-2 | 200 | Mpa |
| Tensile strain | Break | ISO 527-2 | 3.6 | % |
| Bending modulus | ISO 178 | 8400 | Mpa | |
| bending strength | ISO 178 | 250 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 260 | °C |
| 1.8 MPa, Unannealed | ISO 75-2/A | 250 | °C | |
| Melting temperature | ISO 11357-3 | 260 | °C | |
| Linear coefficient of thermal expansion | Flow | ISO 11359-2 | 2.0E-5 | cm/cm/°C |
| Across Flow | ISO 11359-2 | 7.0E-5 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.36 | g/cm³ | |
| Shrinkage rate | 横向Flow | ISO 294-4 | 1.0 | % |
| Flow | ISO 294-4 | 0.20 | % | |
| Water absorption rate | Saturation, 23°C | ISO 62 | 6.0 | % |
| Equilibrium, 23°C, 50% RH | ISO 62 | 1.6 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | -- | ohms | |
| Volume resistivity | IEC 60093 | 1.0E+14 | ohms·cm | |
| Dielectric strength | IEC 60243-1 | 30 | KV/mm | |
| Relative permittivity | 100 Hz | IEC 60250 | 3.80 | |
| 1 MHz | IEC 60250 | 3.50 | ||
| Dissipation factor | 100 Hz | IEC 60250 | 9.0E-3 | |
| 1 MHz | IEC 60250 | 0.016 | ||
| Compared to the anti leakage trace index | IEC 60112 | PLC 1 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.