Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Flame retardancy | | UL 94 | V-0 |
Flame retardancy | | UL 94 | V-0/5VA |
density | | JIS K-7112 | 1.29 |
Flame retardancy | | UL 94 | V-2 |
processability | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTM D-955 | 0.3~0.5 % |
Shrinkage rate | | ASTM D-955 | 0.4~0.6 % |
Basic performance | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ASTM D-570 | 0.16 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Impact strength value | | ASTM D-256 | 69(7) J/m(kgf·cm/cm) |
Impact strength value | | ASTM D-256 | 69(7) J/m(kgf·cm/cm) |
tensile strength | | ASTM D-638 | 79(810) MPa(Kgf/cm |
Flexural modulus | | ASTM D-790 | 3580(36500) MPa(Kgf/cm |
elongation | | ASTM D-638 | 4.0 % |
compressive strength | | ASTM D-695 | 105(1070) MPa(Kgf/cm |
bending strength | | ASTM D-790 | 123(1250) MPa(Kgf/cm |
Rockwell hardness | | ASTM D-785 | 86 M标度 |
Tensile modulus | | ASTM D-638 | 3930(40000) MPa(Kgf/cm |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric breakdown strength | | ASTM D-149 | 30 KV/mm |
permittivity | | ASTM D-150 | 3.07 |
Dielectric tangent | | ASTM D-150 | 0.009 |
permittivity | | ASTM D-150 | 3.16 |
Dielectric tangent | | ASTM D-150 | 0.0008 |
arc resistance | | IEC 112 | 185 V |
Volume resistivity | | ASTM D-257 | 1×10 Ω.cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Load deflection temperature | | JIS K-7207 | 149 °C |
linear expansion coefficient | | ASTM D-696 | 4.0 10 |
linear expansion coefficient | | ASTM D-696 | 6.7 10 |
Load deflection temperature | | JIS K-7207 | 146 °C |
| | UL 746B | 130 °C |
| | UL 746B | 120 °C |
| | UL 746B | 130 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.