PEI 2300-1000 SABIC INNOVATIVE US
179
Form:Granules | Grade:Extrusion grade
Properties:
Glass fiber reinforcedFlame retardantenhance
Typical Applications:
Automotive ApplicationsFitness equipment
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive Applications | Fitness equipment |
| Properties: | Glass fiber reinforced | Flame retardant | enhance |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 85 | J/m |
| 23°C | ASTM D4812 | 430 | J/m | |
| 3.20mm | ASTM D256 | 490 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.25mm | UL 94 | V-0 | |
| 1.2mm | UL 94 | 5VA | ||
| Extreme Oxygen Index | ASTM D2863 | 50 | % | |
| NBSSmokeDensity-Flaming,Ds,4min | ASTME662 | 1.60 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ASTM D638 | 9310 | Mpa | |
| tensile strength | Yield | ASTM D638 | 169 | Mpa |
| Break | ASTM D638 | 159 | Mpa | |
| elongation | Break | ASTM D638 | 3.0 | % |
| Bending modulus | 100mmSpan | ASTM D790 | 8960 | Mpa |
| bending strength | Break,100mmSpan | ASTM D790 | 228 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Elec | UL 746 | 180 | °C | |
| RTI Imp | UL 746 | 170 | °C | |
| RTI Str | UL 746 | 180 | °C | |
| Hot deformation temperature | 0.45MPa,Unannealed,6.40mm | ASTM D648 | 212 | °C |
| 1.8MPa,Unannealed,6.40mm | ASTM D648 | 210 | °C | |
| Vicat softening temperature | ASTM D15255 | 228 | °C | |
| Linear coefficient of thermal expansion | MD:-20to150°C | ASTME831 | 2E-05 | cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.51 | g/cm³ | |
| melt mass-flow rate | 337°C/6.6kg | ASTM D1238 | 5.0 | g/10min |
| Shrinkage rate | MD:3.20mm | Internal Method | 0.20-0.40 | % |
| TD:3.20mm | Internal Method | 0.20-0.40 | % | |
| Water absorption rate | 24hr | ASTM D570 | 0.16 | % |
| Equilibrium,23°C | ASTM D570 | 0.90 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D257 | 3E+16 | ohms·cm | |
| Dielectric strength | 1.60mm,inAir | ASTM D149 | 25 | KV/mm |
| 1.60mm,in Oil | ASTM D149 | 30 | KV/mm | |
| Dielectric constant | 1kHz | ASTM D150 | 3.70 | |
| Dissipation factor | 1kHz | ASTM D150 | 1.5E-03 | |
| 2.45GHz | ASTM D150 | 5.3E-03 | ||
| Arc resistance | ASTM D495 | PLC6 | ||
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 4 | |
| High arc combustion index | HAI | UL 746 | PLC 4 | |
| High voltage arc tracing rate | HVTR | UL 746 | PLC 3 | |
| Hot wire ignition | HWI | UL 746 | PLC 1 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M-Scale | ASTM D785 | 114 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.