Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO1183 | 1.37 g/cm³ |
Melt volume flow rate | | ISO1133 | 35.0 cm3/10min |
Shrinkage rate | | ISO294-4 | 0.90 % |
Shrinkage rate | | ISO294-4 | 0.85 % |
Water absorption rate | | ISO62 | 2.2 % |
Water absorption rate | | ISO62 | 0.80 % |
hardness | Test Condition | Test Method | Test Result |
---|
Ball Indentation Hardness | | ISO2039-1 | 154 Mpa |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | V-0 |
UL flame retardant rating | | UL94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO527-2 | 2650 Mpa |
Tensile stress | | ISO527-2 | 85.0 Mpa |
Tensile strain | | ISO527-2 | 6.9 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO179 | 8.0 kJ/m² |
Charpy Notched Impact Strength | | ISO179 | 8.0 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179 | NoBreak |
Impact strength of simply supported beam without notch | | ISO179 | NoBreak |
Impact strength of cantilever beam gap | | ISO180 | 8.0 kJ/m² |
Impact strength of cantilever beam gap | | ISO180 | 8.0 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC60093 | >1.0E+15 ohms |
Volume resistivity | | IEC60093 | >1.0E+13 ohms·cm |
dielectric strength | | IEC60243-1 | 34 KV/mm |
dielectric constant | | IEC60250 | 3.90 |
dielectric constant | | IEC60250 | 3.80 |
Dissipation Factor | | IEC60250 | 1.7E-03 |
Dissipation Factor | | IEC60250 | 0.014 |
CTI | | IEC60112 | 125 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat Deflection Temperature | | ISO75-2/A | 207 °C |
Linear thermal expansion coefficient | | | 5.2E-05 cm/cm/°C |
RTI Elec | | UL746 | 180 °C |
RTI Elec | | UL746 | 180 °C |
RTI Imp | | UL746 | 180 °C |
RTI Imp | | UL746 | 180 °C |
RTI Str | | UL746 | 190 °C |
RTI Str | | UL746 | 190 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.