PP Copolymer Ducor® 2600 M Ducor Petrochemicals BV

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO 11830.910 g/cm³
melt mass-flow rateISO 11337.5 g/10min
hardnessTest ConditionTest MethodTest Result
ball-indentation hardnessISO 2039-146.0 MPa
Mechanical propertiesTest ConditionTest MethodTest Result
tensile strength YieldISO 527-2/5021.0 MPa
Tensile strainYieldISO 527-2/506.0 %
Tensile modulusISO 527-2/11150 MPa
Tensile strainBreakISO 527-2/50>50 %
shear modulus ISO 6721-2550 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of simply supported beam without notchISO 179/1eU170 kJ/m²
Impact strength of simply supported beam without notchISO 179/1eUNoBreak
Impact strength of simply supported beam without notchISO 179/1eUNoBreak
Impact strength of simply supported beam without notchISO 179/1eUNoBreak
Impact strength of cantilever beam gapISO 180/1A5.0 kJ/m²
Impact strength of cantilever beam gapISO 180/1A6.0 kJ/m²
Impact strength of cantilever beam gapISO 180/1A8.0 kJ/m²
Impact strength of cantilever beam gapISO 180/1A45 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA45 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA6.0 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA7.0 kJ/m²
Charpy Notched Impact StrengthISO 179/1eA9.0 kJ/m²
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureISO 75-2/B80.0 °C
Heat distortion temperatureISO 75-2/A50.0 °C
vicatISO 306/A144 °C
vicatISO 306/B58.0 °C
melting temperatureISO 3146163 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.