PP FB51 BK HANWHA TOTAL KOREA
217
Form:Granules | Grade:Injection grade
Properties:
Flame retardantheat-resistingHigh mobility
Typical Applications:
Electronic fieldElectrical field
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Electronic field | Electrical field |
| Properties: | Flame retardant | heat-resisting | High mobility |
Certificates

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 69 | J/m |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.80mm | UL 94 | V-2 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Yield | ASTM D638 | 29.4 | Mpa |
| elongation | Break | ASTM D638 | 200 | % |
| Bending modulus | ASTM D790 | 1470 | Mpa | |
| injection | Test Condition | Test Method | Test Result | Test Unit |
| Back pressure | 0.490 到 1.96 | Mpa | ||
| Injection pressure | 39.2 到 78.5 | Mpa | ||
| Mold temperature | 40 到 70 | °C | ||
| Spray nozzle temperature | 190 到 210 | °C | ||
| Temperature at the front of the material cylinder | 180 到 200 | °C | ||
| Temperature in the middle of the barrel | 180 到 200 | °C | ||
| Temperature at the rear of the barrel | 170 到 180 | °C | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ASTM D648 | 120 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD:2.00mm | ASTM D955 | 1.5to1.9 | % |
| melt mass-flow rate | 230°C/2.16kg | ASTM D1238 | 8.0 | g/10min |
| density | ASTM D792 | 0.930 | g/cm³ | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 90 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.