PA6 ADDINYL B2 ZV30 ADDIPLAST FRANCE
Properties:
Filler glass fiber reinforced material 30% filler by weight
Typical Applications:
Applications in the automotive field parts under the hood of automobiles
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Applications in the automotive field | parts under the hood of automobiles |
| Properties: | Filler | glass fiber reinforced material | 30% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | kJ/m² | 11 | 19 | |
| Impact strength of cantilever beam gap | kJ/m² | 14 | 22 | |
| Impact strength of simply supported beam without notch | kJ/m² | 65 | 75 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | ,22.0 | ISO 180/1A | 14.0 | KJ/m2 |
| Charpy Notched Impact Strength | ,75 | ISO 179/1eU | 65 | KJ/m2 |
| ,19 | ISO 179/1eA | 11 | KJ/m2 | |
| Bending modulus | ,4800 | ISO 178 | 8200 | MPa |
| Tensile strain (fracture) | ,5.0 | ISO 527-2 | 3.0 | % |
| Tensile stress (fracture) | ,110 | ISO 527-2 | 170 | MPa |
| Bending modulus | MPa | 8200 | 4800 | |
| Tensile strain | Break | % | 3.0 | 5.0 |
| tensile strength | Break | MPa | 170 | 110 |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | ,-- | ASTM E831 | 0.000030 | cm/cm/℃ |
| Melting temperature | ,-DSC法 | ISO 3416 | 220 | ℃ |
| Hot deformation temperature | 1.8 MPa,Unannealed,-HDT | ISO 75-2/Af | 210 | ℃ |
| Linear coefficient of thermal expansion | MD | cm/cm/°C | 3E-05 | -- |
| Melting temperature | °C | 220 | -- | |
| Hot deformation temperature | 1.8MPa,Unannealed | °C | 210 | -- |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | g/cm³ | 1.37 | -- | |
| ,-- | ISO 1183/A | 1.37 | g/cm3 | |
| Shore hardness | ,76 | ISO 868 | 83 | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ,1.0E+11 | IEC 60093 | 1E+15 | ohm-cm |
| Leakage Traceability Index (Solution A) | ,-- | IEC 60112 | 450 | V |
| Dielectric strength | ,30 | IEC 60243-1 | 35 | kv/mm |
| Compared to the anti leakage trace index | SolutionA | V | PLC 1 | |
| Dielectric strength | kV/mm | 35 | 30 | |
| Volume resistivity | ohms·cm | 1E+15 | 1E+11 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | ShoreD | 83 | 76 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.