| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Elongation at Break | 23°C | ASTM D638 | 3 % |
| Tensile modulus | 23°C | ASTM D638 | 6700 MPa |
| bending strength | 23°C | ASTM D790 | 150 MPa |
| Bending modulus | 23°C | ASTM D790 | 5800 MPa |
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 55 J/m |
| tensile strength | 23°C | ASTM D638 | 90 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 0.45MPaUnannealed | ASTM D648 | 185 °C |
| 1.80MPaUnannealed | ASTM D648 | 140 °C | |
| Vicat softening temperature | Melting Temperature | 214-220 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| density | ASTM D792 | 1.46 g/cm³ | |
| Shrinkage rate | MD | ASTM D995 | 0.80-1.0 % |
| Water absorption rate | (23°C,24hr) | ASTM D570 | 0.90-1.0 % |
| 热稳定性 | 90-100 ℃ |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Volume resistivity | ASTM D257 | 1E+12 Ω.cm | |
| Dielectric strength | ASTM D149 | 15 KV/mm |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Rockwell hardness | ASTM D785 | 120 R |
| flame retardant performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | UL -94 | V-2 1.60mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.