PUR,Unspecified Task® 15 Smooth-On, Inc
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Tensile modulus | ASTM D638 | 869 | MPa | |
| tensile strength | Break | ASTM D638 | 18.8 | MPa |
| elongation | Break | ASTM D638 | 20 | % |
| Bending modulus | ASTM D790 | 1170 | MPa | |
| bending strength | ASTM D790 | 38.7 | MPa | |
| Compressive modulus | ASTM D695 | 414 | MPa | |
| compressive strength | ASTM D695 | 37.6 | MPa | |
| thermosetting | Test Condition | Test Method | Test Result | Test Unit |
| Table drying time | 4.0 | min | ||
| stripping time | 23°C | 60 | min | |
| storage stability | 23°C | ASTM D2471 | 6.0 | min |
| Thermosetting mixed viscosity | ASTM D2393 | 600 | cP | |
| Thermosetting components | PartA | 按重量计算的混合比:100.按容量计算的混合比:1.0 | ||
| PartB | 按重量计算的混合比:87.按容量计算的混合比:1.0 | |||
| storage stability | ASTM D2471 | 1.5 | min | |
| Thermosetting mixed viscosity | ASTM D2393 | 500 | cP | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 47.2 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D1475 | 1.12 | g/cm³ | |
| Specific volume | ASTM D1475 | 0.892 | cm³/g | |
| Shrinkage rate | MD | ASTM D2566 | 0.42 | % |
| density | ASTM D1475 | 0.219to0.259 | g/cm³ | |
| Specific volume | 3.79to4.52 | cm³/g | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | ShoreD | ASTM D2240 | 75 | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| CureTime | 2.0 | hr | ||
| Operating intensity | 20.0 | min | ||
| VolumetricExpansion | 4times | |||
| Mixing Ratio | 75A:100Bbyweight |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.