TP, Unspecified 4065 MAIP SRL
0
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| transmissivity | ASTM D1003 | 90.0 % |
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Suspended wall beam without notch impact strength | ASTM D256 | 无断裂 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Bending modulus | ASTM D790 | 1860 MPa | |
| elongation | Break | ASTM D638 | 10 % |
| tensile strength | Break | ASTM D638 | 44.8 MPa |
| Tensile modulus | ASTM D638 | 2070 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Annealed | ASTM D648 | 135 °C |
| 0.45MPa,Unannealed | ASTM D648 | 110 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | MD | ASTM D955 | 0.40to0.60 % |
| melt mass-flow rate | 230°C/3.8kg | ASTM D1238 | 15 g/10min |
| density | ASTM D792 | 1.05 g/cm³ |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.